LSI user guide
Configuration
The LSI have adjustable configuration settings that determine how it functions. These settings can be
accessed by Windows laptop or PC running our SetView software connected via USB cable to the LSI.
These settings can be viewed by performing from SetView a “Synchronize”, and adjusted by performing
an “Adjust Configuration” operation (
).
General Settings
#
Configuration Setting
Minimum Maximum
Factory
1
CAN Bus Interface Speed
0
4
0
2
Log File Incremental Reference Number
0
99999
0
CAN Bus Interface Speed
This sets the speed in Kbps (kilo bits per second) of the CAN bus interface. Options are as follows:
For LRU's to communicate with each other
all of them need to run at the same speed.
Log File Incremental Reference Number
This sets the number (#####) in the log file name (shown below) for the next time logging is performed.
Note that this number is automatically incremented after a new log file was created, meaning this setting
typically does not need any adjustment.
LOG#####.VRL
For example, if this number is 123, the next log file name will be LOG00123.VRL
09/28/21
© 2021 VR Avionics
page 11 of 11
Setting
CAN Bus Speed (Kbps)
0
142.8 (default)
1
125
2
250
3
500
4
1000