INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

TROUBLESHOOTING 

Problem 

Cause 

Solution 

Fail to 
operate. 

Air doesn't 
come out.   

Supply air.   

 

Air pressure is 
too low.   

Adjust to standard 
pressure level.   

Stop in the 
mid position. 

There is a 
foreign object 
in the butterfly 
valve. 

Remove a foreign 
object.   

 

Valve is 
distorted.  

Replace the valve.   

Leakage 
from   
valve seat 

Damaged on 
valve seat.   

Replace the valve. 

 

 

Replace the valve seat. 

Leakage 
from   
valve stem 

Gland packing 
is worn or 
distorted.   

Tighten the gland nut.   

 

 

Replace the gland 
packing. 

For more information contact   
NIPPON VALVE CONTROLS, INC. for consultation. 

Summary of Contents for DN

Page 1: ...stable seal performance is realized PRODUCT CODE D N 9 1 T T F 1 2 3 4 5 6 7 8 9 10 11 1 Actuator TAD TAO TAC 2 Valve DN 3 Voltage 9 Air 4 Sizing code 0 Standard 1 Light 2 Heavy 5 Connection 1 JIS 5K...

Page 2: ...ative pressure Valve type DN Design Wafer type Connection JIS Flanges 5K 10K Fluid Max pressure 1 MPa Size mm 080 to 300 Material Body SCS13A Disk SCS13A Seat F PTFE Stem seal Packing PTFE PRESSURE TE...

Page 3: ...erates the upper shaft of the actuator directly TAO TAC type Classification Single acting type Spring return Actuator type TAO 040 TAC 040 TAO 050 TAC 050 TAO 063 TAC 063 TAO 080 TAC 080 TAO 100 TAC 1...

Page 4: ...ioner Ex dmb II B T5 TIIS EP Smart positioner ES ER Smart positioner with 4 to 20mA output ET EU SHUT by 4 mA OPEN by 20 mA A SHUT by 20 mA OPEN by 4 mA B OPEN by 20 mA SHUT by 4 mA spring return Airl...

Page 5: ...ly Open TAD SHUT by solenoid off OPEN by power to solenoid TAO Airless SHUT OPEN by power to solenoid SHUT by solenoid off Spring return TAC Airless OPEN SHUT by power to solenoid OPEN by solenoid off...

Page 6: ...t the fluid pressure and temperature Use spring washer to prevent from decreasing surface pressure gasket when the temperature change happens frequently Wafer type butterfly valve is put between two s...

Page 7: ...is correct Air or fluid leakage from connection Flow direction of air is correct Air pressure is in the range Nothing interferes with operation when limit switch or solenoid valve is attached ATTENTI...

Page 8: ...doesn t come out Supply air Air pressure is too low Adjust to standard pressure level Stop in the mid position There is a foreign object in the butterfly valve Remove a foreign object Valve is distor...

Reviews: