background image

OSXAB208-EN 

1/7 

NIPPON VALVE CONTROLS, INC. 

Instruction manual

Electric Actuator ABR HBR

SP-1379 

Please read this manual before installation and use.

GENERAL 

The actuator operates at the time of power loss by the built-in 
high-performance shielded battery.   
Built-in battery life is 8 to 9 years at 25 °C.   
It’s possible to use for a wide range of temperature   
(ambient temperature: -20 to +50 °C).   
The battery composed by dry type structure the maintenance of 
saving water is not necessary.   

ABR  :  For AC / DC power   

HBR  :  For AC / DC power  (High speed) 

PRODUCT CODE 

 

A B R -  3  0  0  -  1             

 

H B R -  3  0  0  -  1  -  Q         

-        -    -   

(1) 

 

(2) 

  (3)    (4)         

(1) Actuator 

ABR     
HBR     

(2) Torque 

300    
700    
02K   
06K   

(3) Voltage

1 : 100 / 110 V AC 
2 : 200 / 220 V AC 
0 : 24 V DC 

(4) Operation mode 

Nil : Mode A 

Q  : Mode B 

HBR (06K)

HBR (02K)

ABR (300 / 700)

HBR (300 / 700)

Summary of Contents for ABR-300 Series

Page 1: ...is 8 to 9 years at 25 C It s possible to use for a wide range of temperature ambient temperature 20 to 50 C The battery composed by dry type structure the maintenance of saving water is not necessary...

Page 2: ...N HOLD Battery out Hold the current valve position Battery Compact seal lead acid battery 12 V 2 5 Ah It is recommend to exchange a battery for every 5 years at 25 C Charge system Constant voltage cha...

Page 3: ...A SHUT OPEN SHUT Factory setting Option Q Mode B OPEN SHUT OPEN Setting is required Standby mode Mode A FINISH mode SHUT OPEN HOLD SHUT HOLD mode HOLD Mode B FINISH mode OPEN SHUT OPEN HOLD mode HOLD...

Page 4: ...ttery bracket 21 Battery 4 Motor cover 10 Transformer 16 Bracket fix screw 22 Rubber packing 5 Motor 11 Drive shaft 17 Battery connector 23 Earth screw M3 6 Control board 12 Manual clutch 18 Relay boa...

Page 5: ...spection and replacement work Maintenance space more than 70 mm upward from the actuator is required Be sure to enough space around the actuator for battery replacement CAUTION AFTER PIPING Until the...

Page 6: ...cycle is that 3 minutes 20 of 15 minutes operation is possible The calculated value obtained by dividing 3 minutes by the operation time is the number of times of operation within 15 minutes ATTENTION...

Page 7: ...Confirm existence of abnormal noise and vibration during operation Confirm whether screws are loose or not Confirm that water or condensation no remains in the actuator Turn off the power and check if...