VPI MONTEST-LCD Installation And Operation Manual Download Page 9

 

 

6

 

OPERATION 

 
The following are the normal operational steps for using the MONTEST-LCD.  
 
1.  Connect the monitor to the MONTEST-LCD.  See the section on "CONNECTIONS" (page 2) for details. 
 
2. Turn 

ON

 the MONTEST-LCD power.  The MONTEST-LCD can be used with the AC adapter, or the internal batteries.   

 
3. Use 

the 

GROUP

 button to select the group of scan formats to be used.  See the tables under SCAN FORMATS (pages 8 and 

9),  as required. 

 
4. Use 

the 

NEXT

 and 

PREVIOUS

 buttons to step through the scan formats until the desired scan format is found. 

 
5. The 

ALT

 button can be used to look at the additional screens of LCD data.  Also the pixel time, sync type, and sync polarity 

can be reviewed or changed.   

 
6.  Once the desired scan format is displayed, pushing the 

SELECT

 button will turn ON the video and sync outputs.  The raster 

icon will then be displayed on the LCD and the raster video pattern is output to your monitor. 

 
7.  Change the pattern, colors, and intensity as desired. 
 
8. Pushing 

the 

SELECT

 button again will turn OFF the video and sync outputs.  Also changing the scan format with 

GROUP

NEXT 

or 

PREVIOUS

 will turn OFF the video and sync outputs. 

 
 
 
 

CHANGING BATTERIES 

 
The MONTEST-LCD can be powered by 6 alkaline C-size batteries.  To change the batteries, follow these steps:    
 
1.  Normal electrostatic discharge (ESD) handling precautions should be observed when the enclosure of the MONTEST-LCD is 

open.  Touch a grounded surface before performing any hardware procedure. 

2.  Turn OFF the power and remove all connections to the MONTEST-LCD. 
3.  Place the MONTEST-LCD upside down on a work surface. 
4.  Remove the 2 Phillips head screws that hold the top and bottom of the enclosure together. 
5.  Carefully turn the MONTEST-LCD right side up, holding the enclosure together. 
6.  Lift off the top of the enclosure to expose the battery holder. 
7.  Install 6 new alkaline C-size batteries noting the battery polarity marked on the battery holder. 
8.  Reverse this procedure to reassemble the MONTEST-LCD. 
 

Note: Dead batteries should be removed from the MONTEST-LCD to prevent damage caused by acid leaking from a  
battery.  

 

Summary of Contents for MONTEST-LCD

Page 1: ...RY ALT BLUE GREEN RED INTEN PATTERN SELECT GROUP PREVIOUS NEXT SYNC POLARITY PIXEL TIME CROSS HATCH FULL RASTER GRAY SCALE COLOR BARS MONTEST LCD NTI NETWORK TECHNOLOGIES INCORPORATED ON Tel 330 562 2...

Page 2: ...in this manual is for information only and is subject to change without notice Video Products Incorporated reserves the right to make changes in the product design without reservation and without not...

Page 3: ...Main Screen 3 Alternate Screen 3 B Screen 3 C Screen 3 Examples of Display Screens 3 SWITCH INDICATOR FUNCTIONS 4 OPERATION 6 CHANGING BATTERIES 6 TROUBLESHOOTING 7 SCAN FORMATS 8 SPECIFICATIONS 10 S...

Page 4: ...HD MAC II 15 pin D SUN 13W3 and BNC 5 Versatile and selectable sync outputs for composite sync on green and horizontal vertical with selectable polarity The LCD display clearly shows the user the scan...

Page 5: ...connector Other monitors with a 13W3 type connector may have a different pin out Consult the monitor s manual for the monitor s pin out Those monitors with a different pin out should be connected wit...

Page 6: ...selected Raster Color bars Gray bars Hatch Frequency Horizontal KHz and Vertical Hz scan frequency Alternate Screen No Timeout NT is displayed if the 10 minute video display timeout is OFF Selectable...

Page 7: ...The current MONTEST LCD settings are stored when a scan format is selected These settings are recalled at power up restoring the last settings selected PATTERN Steps through the four video output patt...

Page 8: ...TIME When the alternate screen is displayed the TIME button will alternate the video 10 minute timeout ON and OFF NT on the LCD display indicates No Timeout is selected When the timeout has occurred...

Page 9: ...ty as desired 8 Pushing the SELECT button again will turn OFF the video and sync outputs Also changing the scan format with GROUP NEXT or PREVIOUS will turn OFF the video and sync outputs CHANGING BAT...

Page 10: ...Check connections Make sure scan format is selected see SELECT page 4 Is timeout active see TIME page 5 INTEN indicator is flashing If timeout is active this will flash see TIME page 5 Video on monit...

Page 11: ...200 60 75 0 MAC Format Type Pixels x Lines V Freq Hz H Freq KHz HS VS MAC01 MAC384 512 x 384 70 31 5 MAC02 MAC480 640 x 480 67 35 0 MAC03 MAC480 640 x 480 72 37 6 MAC04 MAC624 832 x 624 75 49 7 MAC05...

Page 12: ...68K 1152 x 864 75 67 5 60s18 MAC870 1152 x 870 75 68 6 60s19 VESA69K 1024 x 768 85 68 7 Format Type Pixels x Lines V Freq Hz H Freq KHz HS VS 70s01 MAC1080 1920 x 1080 60 70 2 70s02 SVGA768 1024 x 768...

Page 13: ...izontal Timing Set with 31 25 ns resolution Vertical Timing Set with 1 horizontal line resolution Sync Type Selectable with default settings Horizontal and Vertical H V Composite CMP Sync On Green SOG...

Page 14: ...mp TTL levels All outputs protected outputs limited to 7 to 5 7 volts Note Connect to only one output at a time The output signals are wired to the connectors in parallel Connecting multiple outputs s...

Page 15: ...EFORMS Sync Front Porch Acitve video Back Porch RGB Video one line 0 7V 0V 5V 0V Video with Sync on Green 0 7V 0V 0 3V Horizontal Sync Horizontal Sync Vertical Sync Composite Sync Vertical Timing Hori...

Page 16: ...which will void your Warranty If you purchased an adapter with a 2 1x5 5mm female plug make sure the PLUG CENTER is POSITIVE Plug Installation 1 Cut the small adapter plug off of the end of your AC ad...

Page 17: ...62 2622 for information regarding repairs and or returns A return authorization number is required for all repairs returns MONTEST LCD SERIAL NO ______________________________ DATE ___________________...

Reviews: