VTAC USER MANUAL
VPC
10/10/2022
For more information visit vpc.com
17
RETENTION INSERT INSTALLATION/REMOVAL-
SIM MODULES AND i2 MX RECEIVERS
PART # 510 170 101, 510 171 101, 610 151 105, 910 112 130
TOOLS REQUIRED
VTAC Extraction Tool
INSTALLATION
1.
Install VTAC Right Angle Insert(s) onto PCB (see previous pages).
2.
Fasten VTAC Retention Insert to PCB using the two provided pan head Phillips
screws.
3.
Ensure that the VTAC Retention insert(s) is aligned with the corresponding
module/ receiver position(s). Also, ensure that any VTAC Right Angle Inserts are
aligned with corresponding VTAC Pass-Thru Inserts.
4.
Apply gentle pressure and install the retention insert(s) into the rear (wiring
side) of the module shown (
Figure A
).
REMOVAL
1.
Extract the VTAC Retention Insert(s). The PCB assembly will be extracted
(
Figure B
). The VTAC Pass-Thru Inserts will remain in the module.
Figure A. Installation
VTAC RETENTION
INSERT
Figure B. Removal
PUSH
PLUNGER