9050 USER MANUAL
VPC
07/19/2022
For more information visit vpc.com
17
ITA will not properly engage with receiver.
ITA is possibly out of alignment or module are mismatched.
•
Remove and inspect the ITA for proper alignment.
•
Check for foreign objects/tools obstructing mating.
•
Inspect module configuration. Ensure ITA module placement and type match that of each receiver module.
•
Inspect for any bent or incorrectly placed pins.
•
Verify the orientation of the receiver and ITA modules.
Excessive force is needed to engage the handle.
(Typical contact load- approximately 35 lbs. force)
ITA is possibly out of alignment or module are mismatched.
•
See above troubleshooting steps
ITA will not engage with the receiver after attempting above troubleshooting steps.
Contact VPC – unauthorized user adjustments to the system will void the warranty.
No continuity upon engagement.
•
When replacing an ITA contact, the mating contact on the receiver side should also be inspected and replaced if necessary.
•
Check wiring and replace if necessary.
•
Contact not secured in module.
•
Contact damage. Visually inspect all contacts for damage to potentially isolate damaged pin prior to checking for continuity with a multi-meter.
A “short ” in the wiring upon engagement.
•
Damaged contact(s) may cause high resistance. Upon replacing a contact in the ITA, the mating contact on the receiver side should also be inspected and
replaced, if necessary.
•
Check wiring and replace, if necessary.
Receiver and ITA will not disengage.
Engagement mechanism within the receiver may be faulty.
Contact VPC – unauthorized user adjustments to the system will void the warranty.
Handle feels/appears loose.
•
Refer to drawing for tightening instructions:
TROUBLESHOOTING
LEFT HANDLE
RIGHT HANDLE
TIGHTEN SCREW TO DESIRED
SETTING WITH FLATHEAD
SCREWDRIVER
TIGHTEN SCREW TO DESIRED
SETTING WITH FLATHEAD
SCREWDRIVER