background image

1 Shock

2 Trunk / Hood

3 Door

APSSECRS

Security and Remote Start

Quick Installa�on Guide

For Complete Installa�on Guide and Technical Support 

Please Visit

www.voxxuniversity.com

Or Call

1-800-225-6074

No�fica�ons

Feature Programming

Remote Programming

1 Chirp

2 Chirp

3 Chirp

4 Chirp

5 Chirp

6 Chirp

1 Lock / Unlock Func

on

500ms

3.5sec

500ms L, DBL UL

DBL L, 500ms UL

DBL L, DBL UL

500ms L, 350ms UL

2 Igni

on Lock

OFF

ON

3 Igni

on Unlock

OFF

Unlock All

Unlock Driver

4 Exterior Illumina

on

OFF

With Arm

With Disarm

With Arm & Disarm

5 Auto Relock

OFF

Auto Lock Only

Auto Lock & Arm

6 Auto Arming / Locking

OFF

Auto Arm Only

Auto Lock & Arm

7 No

�fi

ca

on Sound

Both

Siren

Horn

8 Horn Timing

16ms

30ms

40ms

50ms

10ms

9 Valet Override Method

Valet

Custom Code

Stand Alone Valet

10 Driver Priority Unlock

OFF

ON

11 Silent Choice

OFF

From Transmi

tt

er

OEM Style

12 Security Pro

fi

le

All On

Doors o

ff

Hood / trunk O

ff

All O

ff

All On w/ OEM RS

13 Door Trigger Input

Nega

ti

ve

Posi

ve

14 Park Light / Trunk Swap

OFF

ON

15 Data Port Protocol

ADS

DBI

16 Dome Light Delay Timer

OFF / Program

15sec

30sec

45sec

60sec

120sec

17 Alarm Trigger Legnth

30sec

45sec

60sec

90sec

120sec

1 Chirp

2 Chirp

3 Chirp

4 chirp

5 Chirp

6 Chirp

1 Defrost Output

Pulsed

10min

RS Run

me

2 RS Start No

�fi

ca

on

ON

OFF

3 RS Run

me

15min

20min

45min

60min

5min

10min

4 RS Parking Lights

Steady

Flashing

5 Engine Con

fi

rma

on

Tach

Voltage

Data

Hybrid

6 Voltage Level

>0.5v B4 Start

<0.5v B4 Start

7 Igni

on 2 Output

Igni

ti

on

Accessory

Start

8 Igni

on 3 Output

Igni

ti

on

Accessory

Start

9 Accessory Output

Accessory

Igni

on

Start

10 Transmission

Auto

Manual

11 Max Crank Time

0.8sec

1.0sec

1.5sec

2.0sec

3.0sec

4.0sec

12 Diesel Delay

OFF

Diesel 5

Diesel 10

Diesel 15

Diesel 20

Diesel 30

13 Temperature Start

OFF

14F

5F

0F

-4F

-14F

14 Crank Dura

on

Averaging

Preset

15 RS Shock Override

Shunt un

ti

l Clear

Shunt RS Cycle

Shunt From TX

16 Turbo Timer

OFF

3min

5min

10min

17 Start Ac

va

on

Two Press

One Press

Three Press

18 RS Lock Func

on

No Change

UL Before L A

er

UL Before Start

Lock A

er Start

19 Factory Disarm Output

Single Pulse

Double Pulse

350ms

500ms

800ms

Same As Bank 2, F1

20 Addi

onal Unlock Pulse

No Pulse

IGN, ACC, GWR

IGN,ACC,GWR,PASD

Fe

at

ur

es

Feature Bank 2

Op

ons

Fe

at

ur

es

Feature Bank 3

Op

ons

10 Second Pulse

15 Second Pulse

20 Second Pulse

30 Second Pulse

Push & Hold

Latch ON/OFF

Latch 10min w/ RS

Latch Run

me

5 Second Pulse

1 Second Pulse

Headlight

Defrost

LED

Ch. 4 AUX

Ch. 5 AUX

Ch. 6 AUX

Ch. 7 AUX

Factory Disarm

Factory Arm

Accessory

Pulse During Crank

Pulse A

er Shutdown

Lock

Unlock

2nd Unlock

Trunk

Remote Start Status

Igni

on

Ground While Armed

Ground While Disarmed

Domelight

2020  Voxx Electronics. All Rights Reserved.

Tach Programming

1 Run

me Expired

2 Remote Shutdown

3 Brake On

4 Manual Mode

5 Hood Open

6 Low / No Tach

7 Tach Programming

8 High Tach

The Feature Banks below can also be programmed using the FlashLogic Weblink or Weblink Mobile.

Nega�ve Output Control (NOC)

Nega�ve output control allows any NOC to be programmed for any one of the op�ons 

below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.

AUX Output Control

Any AUX output can be configured using the AUX Control Menu. This feature is only 

accessible via FlashLogic Weblink or Weblink Mobile.

Alarm

When the alarm is triggered the system will provide feedback to the user. Upon disarm, 

the system will beep 4x and flash the LED to indicate the Alarm Trigger Zone.

Chirp Delete

System ARM/DISARM chirps can be toggled ON or OFF without entering the Feature 

Bank programming.

1. 

Turn the igni�on key ON/OFF.

2. 

Press and release the valet button three (3) �mes.

The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This 

feature will not affect alarm trigger or programming. 

User Programmable LED

System LED no�fica�ons can be turned ON or OFF without entering Feature Bank 

programming.

1. 

Turn the igni�on key ON/OFF, ON/OFF.

2. 

Press and hold valet button for five (5) seconds.

The LED will flash one (1) �me for ON, two (2) �mes for OFF. This feature will not affect 

LED flash during programming.

The APSSECRS does not include an RF remote kit. The RF remote kit Includes two (2) 

remotes,  one (1) antenna, and one (1) cable. When added, remotes must be programmed 

to the system. Remote Programming is located in Feature Bank 1. To enter Remote Auto 

Programming:

1. 

Turn the igni�on key to ON.

2. 

Press and release the valet button three (3) �mes. System will beep and flash the 

parking lights one (1) �me.

Press the lock button on each remote. The system will beep one (1) �me to indicate the 

remote has been programmed. If programming one (1) button remotes, press the Start 

button. Only primary remote func�ons are auto programmed. This Includes Lock, Unlock, 

and Trunk/Start.

If using AUX output control, you must manually program the AUX output channels to 

the remote. Please see the complete installa�on guide for manual remote programming 

instruc�on.

Note: If programming 2-Way remotes, wait for the remote to beep before programming 

addi�onal remotes. This beep is confirma�on that a 2-Way response has been received 

from the main module.

The APSSECRS Feature Banks can be programmed by using the valet button and remote. 

To enter Feature Bank programming:

1. 

Turn the igni�on key to ON.

2. 

Press and release the valet button three (3) �mes. System will beep and flash lights 

one (1) �me for Feature Bank 1, Remote Programming.

3. 

Cycle igni�on key OFF/ON. System will beep and flash lights two (2) �mes for 

Feature Bank 2.

4. 

Press valet button to cycle features. LED will flash to display feature number.

5. 

Press lock button to cycle op�ons. System will beep to indicate op�on number.

6.  Cycle igni�on key OFF/ON. System will beep and flash lights three (3) �mes for 

Feature Bank 3.

7. 

Press valet button to cycle features. LED will flash to display feature number.

8.  Press lock to cycle op�ons. System will beep to indicate op�on Number.

The installer must manually configure the Engine Confirma�on method in Feature Bank 

3, Feature 5. The default method is “Tach”. When using the default “Tach” method, the 

vehicle tach rate must be programmed. To enter tach rate programming:

1. 

Turn the igni�on key ON.

2. 

Press and release the valet button three (3) �mes.

3. 

Turn the igni�on key OFF.

4. 

Press and hold valet button.

5. 

While holding valet button, start the engine using the key.

6.  Hold the valet button for approximately ten (10) seconds. If connected to the vehicle 

Tach source, the system will flash the parking lights one (1) �me every second.

7. 

Release the valet button. The system will turn on the parking lights for two (2) 

seconds to indicate the tach rate is programmed.

The tach rate can also be programmed without the use of a valet button. This is helpful 

when using the OEM remote of CarLink system to control this module. To program the tach 

rate without a valet button:
1. Turn the igni�on key to the ON posi�on and start the vehicle’s engine.

2. Wait for Engine RPM to lower to a normal idle.

3. Press and hold the vehicle’s brake pedal.

4. Press the LOCK button on the OEM remote or the Carlink App.

Note:

 Programming tach signal via OEM or Telema�cs control is only available on Firmware 

v1.47 or Higher.

Remote Start

If the remote start fails to start the vehicle, the system will flash the vehicle parking 

lights to indicate the cause.

REV. B

Data Protocol Selec�on 

The default data port protocol of this model is ADS (iDatalink 2-Way). This model is capable 

of detec�ng the correct data port protocol (ADS or DBI) and automa�cally configuring 

Feature Bank 2; Feature 18. To ini�alize the detec�on procedure:

1. 

Press and hold the valet button.

2. 

Cycle the vehicle’s Igni�on ON/OFF two (2) �mes.

3. 

Release the valet button. 

The system will automa�cally detect and set the correct data port protocol, ADS or DBI.

Note: 

This feature is only available on module firmware v2.0 or higher.

Dome Delay Programming

This system can be programmed to ignore the vehicle’s theater dimming dome light. This 

feature will be used when connec�ng the door trigger input to the dome light circuit for 

alarm trigger.

Start with all doors closed and the vehicle dome light off.

1. 

Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.

2. 

Open and close the driver door.

The system will monitor the dome light circuit. When the dome light turns off the system 

will set the delay �me and add an addi�onal two (2) seconds.

Dome Delay Reset

1. Key ON/OFF, ON/OFF, ON/OFF.

2. Press and hold valet button for five (5) seconds.

The system will beep one (1) �me to indicate reset is complete.

Programmable Input Control

Programmable Input Control allows any PIC be configured to one of the op�ons listed 

below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.

N.C. Door Trigger

External Start Ac

va

on

Pre-Warn Shock Trigger

Diesel Glow Plug

Door Trigger

Full Shock Trigger

Trunk Trigger

Parking Brake

Hood Trigger

Brake

Reviews: