1 Shock
2 Trunk / Hood
3 Door
APSSECRS
Security and Remote Start
Quick Installa�on Guide
For Complete Installa�on Guide and Technical Support
Please Visit
www.voxxuniversity.com
Or Call
1-800-225-6074
No�fica�ons
Feature Programming
Remote Programming
1 Chirp
2 Chirp
3 Chirp
4 Chirp
5 Chirp
6 Chirp
1 Lock / Unlock Func
�
on
500ms
3.5sec
500ms L, DBL UL
DBL L, 500ms UL
DBL L, DBL UL
500ms L, 350ms UL
2 Igni
�
on Lock
OFF
ON
3 Igni
�
on Unlock
OFF
Unlock All
Unlock Driver
4 Exterior Illumina
�
on
OFF
With Arm
With Disarm
With Arm & Disarm
5 Auto Relock
OFF
Auto Lock Only
Auto Lock & Arm
6 Auto Arming / Locking
OFF
Auto Arm Only
Auto Lock & Arm
7 No
�fi
ca
�
on Sound
Both
Siren
Horn
8 Horn Timing
16ms
30ms
40ms
50ms
10ms
9 Valet Override Method
Valet
Custom Code
Stand Alone Valet
10 Driver Priority Unlock
OFF
ON
11 Silent Choice
OFF
From Transmi
tt
er
OEM Style
12 Security Pro
fi
le
All On
Doors o
ff
Hood / trunk O
ff
All O
ff
All On w/ OEM RS
13 Door Trigger Input
Nega
ti
ve
Posi
�
ve
14 Park Light / Trunk Swap
OFF
ON
15 Data Port Protocol
ADS
DBI
16 Dome Light Delay Timer
OFF / Program
15sec
30sec
45sec
60sec
120sec
17 Alarm Trigger Legnth
30sec
45sec
60sec
90sec
120sec
1 Chirp
2 Chirp
3 Chirp
4 chirp
5 Chirp
6 Chirp
1 Defrost Output
Pulsed
10min
RS Run
�
me
2 RS Start No
�fi
ca
�
on
ON
OFF
3 RS Run
�
me
15min
20min
45min
60min
5min
10min
4 RS Parking Lights
Steady
Flashing
5 Engine Con
fi
rma
�
on
Tach
Voltage
Data
Hybrid
6 Voltage Level
>0.5v B4 Start
<0.5v B4 Start
7 Igni
�
on 2 Output
Igni
ti
on
Accessory
Start
8 Igni
�
on 3 Output
Igni
ti
on
Accessory
Start
9 Accessory Output
Accessory
Igni
�
on
Start
10 Transmission
Auto
Manual
11 Max Crank Time
0.8sec
1.0sec
1.5sec
2.0sec
3.0sec
4.0sec
12 Diesel Delay
OFF
Diesel 5
Diesel 10
Diesel 15
Diesel 20
Diesel 30
13 Temperature Start
OFF
14F
5F
0F
-4F
-14F
14 Crank Dura
�
on
Averaging
Preset
15 RS Shock Override
Shunt un
ti
l Clear
Shunt RS Cycle
Shunt From TX
16 Turbo Timer
OFF
3min
5min
10min
17 Start Ac
�
va
�
on
Two Press
One Press
Three Press
18 RS Lock Func
�
on
No Change
UL Before L A
�
er
UL Before Start
Lock A
�
er Start
19 Factory Disarm Output
Single Pulse
Double Pulse
350ms
500ms
800ms
Same As Bank 2, F1
20 Addi
�
onal Unlock Pulse
No Pulse
IGN, ACC, GWR
IGN,ACC,GWR,PASD
Fe
at
ur
es
Feature Bank 2
Op
�
ons
Fe
at
ur
es
Feature Bank 3
Op
�
ons
10 Second Pulse
15 Second Pulse
20 Second Pulse
30 Second Pulse
Push & Hold
Latch ON/OFF
Latch 10min w/ RS
Latch Run
�
me
5 Second Pulse
1 Second Pulse
Headlight
Defrost
LED
Ch. 4 AUX
Ch. 5 AUX
Ch. 6 AUX
Ch. 7 AUX
Factory Disarm
Factory Arm
Accessory
Pulse During Crank
Pulse A
�
er Shutdown
Lock
Unlock
2nd Unlock
Trunk
Remote Start Status
Igni
�
on
Ground While Armed
Ground While Disarmed
Domelight
2020 Voxx Electronics. All Rights Reserved.
Tach Programming
1 Run
�
me Expired
2 Remote Shutdown
3 Brake On
4 Manual Mode
5 Hood Open
6 Low / No Tach
7 Tach Programming
8 High Tach
The Feature Banks below can also be programmed using the FlashLogic Weblink or Weblink Mobile.
Nega�ve Output Control (NOC)
Nega�ve output control allows any NOC to be programmed for any one of the op�ons
below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
AUX Output Control
Any AUX output can be configured using the AUX Control Menu. This feature is only
accessible via FlashLogic Weblink or Weblink Mobile.
Alarm
When the alarm is triggered the system will provide feedback to the user. Upon disarm,
the system will beep 4x and flash the LED to indicate the Alarm Trigger Zone.
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering the Feature
Bank programming.
1.
Turn the igni�on key ON/OFF.
2.
Press and release the valet button three (3) �mes.
The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This
feature will not affect alarm trigger or programming.
User Programmable LED
System LED no�fica�ons can be turned ON or OFF without entering Feature Bank
programming.
1.
Turn the igni�on key ON/OFF, ON/OFF.
2.
Press and hold valet button for five (5) seconds.
The LED will flash one (1) �me for ON, two (2) �mes for OFF. This feature will not affect
LED flash during programming.
The APSSECRS does not include an RF remote kit. The RF remote kit Includes two (2)
remotes, one (1) antenna, and one (1) cable. When added, remotes must be programmed
to the system. Remote Programming is located in Feature Bank 1. To enter Remote Auto
Programming:
1.
Turn the igni�on key to ON.
2.
Press and release the valet button three (3) �mes. System will beep and flash the
parking lights one (1) �me.
Press the lock button on each remote. The system will beep one (1) �me to indicate the
remote has been programmed. If programming one (1) button remotes, press the Start
button. Only primary remote func�ons are auto programmed. This Includes Lock, Unlock,
and Trunk/Start.
If using AUX output control, you must manually program the AUX output channels to
the remote. Please see the complete installa�on guide for manual remote programming
instruc�on.
Note: If programming 2-Way remotes, wait for the remote to beep before programming
addi�onal remotes. This beep is confirma�on that a 2-Way response has been received
from the main module.
The APSSECRS Feature Banks can be programmed by using the valet button and remote.
To enter Feature Bank programming:
1.
Turn the igni�on key to ON.
2.
Press and release the valet button three (3) �mes. System will beep and flash lights
one (1) �me for Feature Bank 1, Remote Programming.
3.
Cycle igni�on key OFF/ON. System will beep and flash lights two (2) �mes for
Feature Bank 2.
4.
Press valet button to cycle features. LED will flash to display feature number.
5.
Press lock button to cycle op�ons. System will beep to indicate op�on number.
6. Cycle igni�on key OFF/ON. System will beep and flash lights three (3) �mes for
Feature Bank 3.
7.
Press valet button to cycle features. LED will flash to display feature number.
8. Press lock to cycle op�ons. System will beep to indicate op�on Number.
The installer must manually configure the Engine Confirma�on method in Feature Bank
3, Feature 5. The default method is “Tach”. When using the default “Tach” method, the
vehicle tach rate must be programmed. To enter tach rate programming:
1.
Turn the igni�on key ON.
2.
Press and release the valet button three (3) �mes.
3.
Turn the igni�on key OFF.
4.
Press and hold valet button.
5.
While holding valet button, start the engine using the key.
6. Hold the valet button for approximately ten (10) seconds. If connected to the vehicle
Tach source, the system will flash the parking lights one (1) �me every second.
7.
Release the valet button. The system will turn on the parking lights for two (2)
seconds to indicate the tach rate is programmed.
The tach rate can also be programmed without the use of a valet button. This is helpful
when using the OEM remote of CarLink system to control this module. To program the tach
rate without a valet button:
1. Turn the igni�on key to the ON posi�on and start the vehicle’s engine.
2. Wait for Engine RPM to lower to a normal idle.
3. Press and hold the vehicle’s brake pedal.
4. Press the LOCK button on the OEM remote or the Carlink App.
Note:
Programming tach signal via OEM or Telema�cs control is only available on Firmware
v1.47 or Higher.
Remote Start
If the remote start fails to start the vehicle, the system will flash the vehicle parking
lights to indicate the cause.
REV. B
Data Protocol Selec�on
The default data port protocol of this model is ADS (iDatalink 2-Way). This model is capable
of detec�ng the correct data port protocol (ADS or DBI) and automa�cally configuring
Feature Bank 2; Feature 18. To ini�alize the detec�on procedure:
1.
Press and hold the valet button.
2.
Cycle the vehicle’s Igni�on ON/OFF two (2) �mes.
3.
Release the valet button.
The system will automa�cally detect and set the correct data port protocol, ADS or DBI.
Note:
This feature is only available on module firmware v2.0 or higher.
Dome Delay Programming
This system can be programmed to ignore the vehicle’s theater dimming dome light. This
feature will be used when connec�ng the door trigger input to the dome light circuit for
alarm trigger.
Start with all doors closed and the vehicle dome light off.
1.
Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.
2.
Open and close the driver door.
The system will monitor the dome light circuit. When the dome light turns off the system
will set the delay �me and add an addi�onal two (2) seconds.
Dome Delay Reset
1. Key ON/OFF, ON/OFF, ON/OFF.
2. Press and hold valet button for five (5) seconds.
The system will beep one (1) �me to indicate reset is complete.
Programmable Input Control
Programmable Input Control allows any PIC be configured to one of the op�ons listed
below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.
N.C. Door Trigger
External Start Ac
�
va
�
on
Pre-Warn Shock Trigger
Diesel Glow Plug
Door Trigger
Full Shock Trigger
Trunk Trigger
Parking Brake
Hood Trigger
Brake