Mechanical Dimensions and Mounting

 

MECHANICAL DIMENSIONS AND MOUNTING 

SCREWS 

LOCATION 

DETAILS 

PENETRATION 

TIGHTENING 

MOUNTING 

M4 

4mm max, including chassis

 

0.5 NM 

OUTPUT MODULES 

M3 x 5, Countersink Posi, 16 Places 

Defined by screw 

0.5 NM 

CHASSIS LID AND FACEPLATE 

M3 x 5, Countersink Posi, 9 Places 

M3 x 30, Countersink Posi, 2 Places 

Defined by screw 

0.5 NM 

Torque settings are for general reference only.  The torque settings shown are the insert manufacturers recommended values. 

 

 

 

Summary of Contents for NEVO+1200 Series

Page 1: ...users and service personnel DE RATINGS Ambient Temperature The input module power must be de rated by 2 5 C above 50 C ambient up to a maximum ambient temperature of 70 C Input Voltage The input module power must be de rated by 10W VRMS below120 VRMS 1200W 120 VRMS 850W 85 VRMS Remember to take the appropriate de rating into consideration before specifying any NEVO 1200 power supply for an applica...

Page 2: ...P 0 5 ABCDEFGH OPA3 9V 24V 30V 15A 300W 450W 150mV 24mV 48mV 240mVPP 0 5 ABCDEFGH Note 1 Output module 30 C base 100 load SR332 issue 2 Method I Case 3 Ground Fixed Controlled Note 2 A Remote Sense B External Voltage control C External constant current control D Current output signal E Current share F Over Voltage protection G Over temperature protection H Dual Slot module SAFETY SPECIFICATIONS Pa...

Page 3: ...CAL DIMENSIONS AND MOUNTING SCREWS LOCATION DETAILS PENETRATION TIGHTENING MOUNTING M4 4mm max including chassis 0 5 NM OUTPUT MODULES M3 x 5 Countersink Posi 16 Places Defined by screw 0 5 NM CHASSIS LID AND FACEPLATE M3 x 5 Countersink Posi 9 Places M3 x 30 Countersink Posi 2 Places Defined by screw 0 5 NM Torque settings are for general reference only The torque settings shown are the insert ma...

Page 4: ...ion Lock 28 30AWG MOLEX 3 1510210600 50058800 Notes 1 Cable 14 18AWG 300V 16A 105 C use appropriately rated crimp terminal 2 Terminal and wire current rating must exceed maximum short circuit output current Eg Output 1 25A 1 25 31 25A 3 Direct equivalents may be used for any connector parts 4 All cables must be rated 105 C min equivalent to UL1015 PART NUMBERS AND ORDERING INFORMATION NEVO Power S...