Configuring Your NEVO Product
The Nevo+1200 power supply is designed to be used as part of an end-system in a restricted environment and therefore should only be accessible to
qualified and trained personnel. Persons attempting to configure a unit must have the necessary knowledge and training before doing so. Incorrect
configuration may cause damage to the power supply and may affect the warranty of the power supply.
Output power modules may be added, replaced or moved by strictly following the sequence of operations described below. Please contact Vox Power or
your distributor for assistance in configuring your power supply. Never assume, always ask.
STEP 1:
If the power supply is being configured for the first time remove the front end unit from the packaging and continue to step two. If the power supply is
being reconfigured always adhere to the rest of this step. Ensure the mains power connection is switched off and then disconnect the main power
connection from the power supply. Take care as the outer surface of the power supply may be hot. Allow the power supply to cool down sufficiently
before handling it. Remove all other connections from the power supply. If the power supply is mounted onto a base plate remove the screws attaching it
to the base plate so that the power supply can be easily handled during configuration. Once all the connections are removed let the power supply stand
for 3 minutes before attempting to configure or re-configure the power supply.
STEP 2:
Removing the screws: At the fan side there are 2 longer and 2 shorter screws, remove only the two longer screws. These are the two screws above and
either side of the input connector. Do not remove the two screws on the outer edges of the faceplate. Proceed to remove the 6 screws on the sides (3
each side) and 17 on the top (2 for each slot and 1 in the centre just below the product label). The lid can now be removed. Ensure that all the output
modules are loose from the lid before removing the lid. For new front end configurations there will not be any output modules in place. Where ever
blanking plates are inserted top screws do not need removing.
Input Connector
Longer Screw (x2)
Shorter Screw (x2)
Side screw (x3 each side)
Top Screws for Modules (x 16)
Top Screw center of unit (x1)
Top Screws for Modules (x 16)
Top Insulator
Winding Board Connection
Output Module
Blanking Plate
Global Signals J2a
Global Signals J2b
Input Signals J6
WARNING!
Do not remove the Top Insulator
.