Connection Plan: 
 

 
 

Configuration of Connections: 

 

1 = Board Battery “-“ (Minus) or  

 Body-Ground 

2= Board Battery “+” (Plus) 
3= Starter Battery “+” (Plus) 
 

Recommended Minimum Cable Cross-Sections: 

Cable Length up to 2 m: 0.5 mm²

 

Cable Length up to 5 m: 1.0 mm²

 

Cable Length from 5 m:  1.5 mm²

 

 
Ensure that cable length is sufficient to facilitate the 
installation. 
 
Carefully screw down stripped cables with all single wires 
to the terminal observing that no single wires jut out 
laterally. 
 
The unit is protected from reverse battery (+ and - mixed 
up). 
 
Lead the cable up to the battery connections! By this, 
incorrect measurements due to voltage losses at the 
power distributors, cables etc. are avoided.

 

 
 
 

Cable Protection:

 Arrange the fuses for protection against 

short-circuits close to the battery.

 

 

 
 
 
 
 
 
 

 
Note:  

Amongst others, the connections of the panel are marked with numbers. The numbering of all VOTRONIC 
display units has been assigned systematically to the corresponding connections. Thus, connection of several 
units is facilitated.

 

The cables in different colours help to avoid malfunctions due to mixed up connections. 

 
 

 

Summary of Contents for 1245

Page 1: ...s the tank displays S the LCD displays S as well as the switch panels and fuse panels S is a useful application The units can be combined perfectly with regard to appearance and their installation is easy see example modular system Installation Choose a well visible and easily accessible location in the living area for installation of the unit The installation place in the front panel of the furni...

Page 2: ...s jut out laterally The unit is protected from reverse battery and mixed up Lead the cable up to the battery connections By this incorrect measurements due to voltage losses at the power distributors cables etc are avoided Cable Protection Arrange the fuses for protection against short circuits close to the battery Note Amongst others the connections of the panel are marked with numbers The number...

Page 3: ...rent the battery voltage tends to the light emitting diode being the brighter one The range of operation of the lead battery 12 V is indicated by the red and green light emitting diodes and it is valid for inferior to normal load current consumption of the battery Green means o k If powerful consumers with high current consumption are used such as inverters the battery voltage might drop below 11 ...

Page 4: ...e purchase date against presentation of the sales slip or invoice The warranty will be void in case of any inappropriate utilisation of the unit if it is used beyond the technical specification in case of improper operation or external intervention We do not assume any liability for any damage resulting hereof The liability exclusion is extended to any service being executed by third which has not...

Reviews: