- 2 -
Connection Plan:
Configuration of Connections:
1 = Board Battery “-“ (Minus) or
Body-Ground
2= Board Battery “+” (Plus)
3= Starter Battery “+” (Plus)
Recommended Minimum Cable Cross-Sections:
Cable Length up to 2 m: 0.5 mm²
Cable Length up to 5 m: 1.0 mm²
Cable Length from 5 m: 1.5 mm²
Ensure that cable length is sufficient to facilitate the
installation.
Carefully screw down stripped cables with all single wires
to the terminal observing that no single wires jut out
laterally.
The unit is protected from reverse battery (+ and - mixed
up).
Lead the cable up to the battery connections! By this,
incorrect measurements due to voltage losses at the
power distributors, cables etc. are avoided.
Cable Protection:
Arrange the fuses for protection against
short-circuits close to the battery.
Note:
Amongst others, the connections of the panel are marked with numbers. The numbering of all VOTRONIC
display units has been assigned systematically to the corresponding connections. Thus, connection of several
units is facilitated.
The cables in different colours help to avoid malfunctions due to mixed up connections.