background image

Important Safety Instructions

EN_1

1. Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions.

5. Do not use this apparatus near water. Clean only with dry cloth.

7. Do not block any ventilation openings. Install in accordance with the manufacturers 
instructions.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 
has two blades with one wider than the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the points where they exit from the apparatus.

13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus 
has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.

14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,
such as vases shall be placed on the apparatus.

15. 

WARNING:

 

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or

moisture.

16. Installation should be done only by qualified personnel and conform to all local codes.

20. 

CAUTION:

 

These servicing instructions are for use by qualified service personnel only. To

reduce the risk of electric shock do not perform any servicing other than that contained in the
operating instructions unless you are qualified to do so.

Website:www.voscom.com

Summary of Contents for VOS-2010FDMR

Page 1: ...VOS 2010FDT R series 2 Channel Video 1 Duplex Data Installation Manual Fiber Optic Transmission Systems VOSCOM TECHNOLOGIES CO LIMITED WWW VOSCOM COM TM...

Page 2: ...on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus 13 Refer all servicing to qualified service personnel Servicing is required when the appar...

Page 3: ...width Power adapter is manufactured by third party and is supplied with fitted screw terminal output cables Power adapter included for standalone US European UK or Australian power plug Please feel fr...

Page 4: ...h the front BNC and rear BNC of the same channel Also since each video channel is factory terminated to 75 ohm unused BNCs should not be used for loop through video connections 4 Data Connector 4 Pin...

Page 5: ...ontact us support voscom com 4 Pin Terminal Block Pin Conect Data Rs485 A Conect Data Rs485 B None Input Output 1 2 3 4 DATA 1 2 3 4 Input Output Conect Ground GND Input Output 4 Pin Terminal Block Pi...

Page 6: ...ach video channel is factory terminated to 75 ohm unused BNCs should not be used for loop through video connections Typical Connection DC5V 2A Power Supply Power Supply DC5V 2A Video Input Optic Outpu...

Page 7: ...he unit can be placed on a desktop or can be mounted to a wall NOTE Before mounting the VOS 2010FDT transmitter VOS 2010FDR receiver please ensure that there is adequate space at both ends for viewing...

Page 8: ...WER LED indicator that illuminates when power is applied to the rack unit 5 Fiber optic plug in modules video cards can be installed into any of the available 14 slots of the card cage Most modules re...

Page 9: ...rs and associated troubleshooting guidelines Table A Power Links Indicator Status Meaning Possible Cause Corrective Action Video LED VIDEO 1 VIDEO 2 Light Incoming video signal is present on thechanne...

Page 10: ...Data is not present on the channel No action required Data connection is faulty Check data connections Data communication cable is defective Replace cable The optical signal is not being received Rem...

Page 11: ...repair replacements nonwarranty repairs advance replacements and credit returns To obtain an RMA Download from www voscom com and please complete the RMA as much detail as possible then send the RMA t...

Page 12: ...repair department will evaluate the returned product to determine whether it is a warranty or non warranty replacement and bill you accordingly We will invoice advance replacements at shipment and cre...

Page 13: ...ut notice 2 You can download the latest PDF document here www voscom com 3 Online Technical Support please E mail support voscom com 4 More detail product information please E mail sales voscom com or...

Page 14: ...R MOISTURE DO NOT LOOK INTO OPTICAL PORTS WITH POWER ON Headquarters Information Distributor Information VOSCOM TECHNOLOGIES CO LIMITED Hangzhou Zhejiang P R CHINA 310004 Tel 86 571 87389389 Fax 86 57...