Rack-mount Installation
En_6
Installation Instructions
Typical Configurations:
1:
Install the video card into a standard 19inch rack, using user-supplied rack-mounting
hardware. Be careful to not damage exposed objects on the back of the card cage unit.
2:If a secondary earth ground connection is needed, a grounded wire with a ground lug can be
attached to the rack using the protruding screw provided on the right side of the chassis.
3:If desired, blank panels may be installed to cover unused slots. A single blank panel covers a
single slot opening.
4:Each fiber optic plug-in module is equipped with a POWER LED indicator that illuminates
when power is applied to the rack unit.
5:Fiber optic plug-in modules(video cards) can be installed into any of the available 14 slots
of the card cage. Most modules require only a single slot width, but others, such as the 8-Ch
video Series, require two slot widths.
VOS-CH10:
19 inch 10U,14 video card slots, only suit for 16-channel video cards.
Support two slide-in power supply AC100V~AC240V, one for redundancy.
Website:www.voscom.com
The VOS-16010FBT transmitter/VOS-16010FBR receiver can be installed into our rack mount
chassis, VOS-CH10, which can be mounted into an industry-standard 19-inch equipment rack.