Electrical connections
Fig. 33
Maintenance / Cleaning
Fig. 34-36
Important information
concerning the environmentally
compatible disposal
IN CERTAIN EUROPEAN UNION COUNTRIES THIS
PRODUCT
DOES
NOT
FALL
WITHIN
THE
REQUIREMENTS
OF
THE
NATIONAL
LAWS
IMPLEMENTING
DIRECTIVE
WEEE,
AND
IN
THESE COUNTRIES THE PRODUCT IS NOT
SUBJECT TO SEPARATE DISPOSAL OPERATIONS
AT THE END OF ITS WORKING LIFE.
This product conforms to EU Directive2002/96/EC.
This appliance bears the symbol
of the barred waste bin. This
indicates that, at the end of its
useful life, it must not be disposed
of as domestic waste, but must be
taken to a collection centre for
waste electrical and electronic
equipment,
or
returned
to
a
retailer on purchase of a replacement.
It is the user's responsibility to dispose of this
appliance through the appropriate channels at the
end of its useful life. Failure to do so may incur the
penalties established by laws governing waste
disposal.
Proper differential collection, and the subsequent
recycling,
processing
and
environmentally
compatible disposal of waste equipment avoids
unnecessary damage to the environment and
possible related healthrisks, and also promotes
recycling of the materials used in the appliance.
For further information on waste collection and
disposal, contact your local waste disposal service,
or the shop from which you purchased the appliance.
Manufacturers
and
importers
fulfil
their
responsibilities
for
recycling,
processing
and
environmentally compatible disposal either directly or
by participating in collective systems.
9
ENGLISH
Extract Ventilation Rates
For U.K. Market only:
•
The product is designed to Comply with U.K. Building
Regulations Approved Document F1: Means of
Ventilation System 3 – Continuous mechanical extract.
The installation rates are:
Table 1.1 a - Extract ventilation rates
Room
Continuous extract
Minimum high rate
(l/s)
Minimum low rate
Kitchen
13
Total extract rate
must be at least the
whole building ven-
tilation rate in table
1.1 b
Utility room
8
Bathroom
8
Sanity
accommodation
6
**
**
UK: For sanitary accommodation ONLY, as an alternative,
the purge ventilation given in ADF
Appendix B can be used where security is not an issue. In
this case the “minimum high extract rate” for the sanitary
accommodation should not be included in the calculation.
Whole Building Ventilation Rates
Table 1.1 b - Whole building ventilation rates
Number of bedrooms in
dwelling
1
2
3
4
5
Whole building ventilation
rate
A - B
(l/s)
13
17
21
25
29
A. In addition, the minimum ventilation rate should be not less
than 0.3 l/s per m
2
internal floor area (this includes each floor,
e.g. for a two-storey building, add the ground and first floor
area).
B. This is based on two occupants in the main bedroom and a
single occupant in all other bedrooms. This should be used as
the default value. If a greater level of occupancy is expected,
then add 4 l/s per occupant.
•
The product should be used in conjunction with Vortice
Flexible Aluminium Ducting or Vortice Rigid Modular
Circular Plastic Ducting.
Summary of Contents for VORT NOTUS
Page 6: ...26 5 5 115 mm 7 7 6 6 8 8...
Page 7: ...27 9 9 a cura dell Installatore 11 10 10 VORT NOTUS 12 12...
Page 8: ...28 13 13 15 15 mm 102 VORT NOTUS 14 14 16 16 1...
Page 9: ...29 17 17 mm 133 19 19 18 18 20 20...
Page 10: ...30 21 21 23 23 1 22 22 1 24 24 1...
Page 11: ...31 25 25 27 27 26 26 28 28...
Page 12: ...32 29 29 30 30 31 31 32 32...
Page 14: ...34 36 36...