11
VX1500D
2.9 Troubleshooting
This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps
below in sequence until a solution is found. Once the unit operates properly, do not carry out following
steps. If the problem persists, refer servicing to a qualified technician.
Power connected but no fog is emitted:
1. Check the fog fluid in the tank.
2. Check the power supply. Plug the unit into grounded electric power supply socket with proper voltage.
3. Check your controller connection or controller receiver connection. Fulfill controller usage requirements
for distance, etc. Follow procedures listed in controller manual.
4. Check DMX setup.
5. Disconnect fog machine from electric power supply. Replace fuse with one of the same type.
6. Check the thermic protection. The thermic protection for the smoke machine is located on the boiler
inside the unit.
DANGER! Disconnect the power supply before removing any covers. Live parts inside!
- To restore the thermic protection disconnect the power cord from the supply, unscrew the screws
holding the top cover of the unit and remove the cover. Press the button, on the boiler, to restore.
- Replace the cover and retighten the screw.
- Plug main power cord from the fog machine into the appropriate power supply socket. Wait a few
minutes for heating element to heat up. When the heating process is completed the fog machine is
ready for use.
- Contact technical service if the problem persists.
2.8 DMX control
Channel
Function
1
Smoke output
2
Interval time
Summary of Contents for VX1500D
Page 1: ...I GB Manuale Utente User Manual VX1500D DMX FOG MACHINE...
Page 2: ...REV 001 05 11...
Page 14: ......
Page 26: ......
Page 29: ......
Page 30: ......
Page 31: ......