12
5
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can
connect with the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 120*76*28mm.
13. Dual relay outputs for door opening, door status detecting, open door
by button. The function of door status detecting is for ZONE 1 only.
Working conditions:
Current and voltage requirements:
Applicable card mode:
Effective distance:
Capacity:
temperature: -20 C ~ +50 C
RH: ˇ95%
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ˇ80mA
working current: ˇ110mA
EM ID card(Default)
T5557/T5567 card(Setting required)
5cm
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
o
o
After adding cards, a sound "BI" as reminder. Swipe the first added
card or input the first added card serial number(8 digits), a sound "BI"
as reminder, means added in successfully.
Press the button to quit setting mode.
Modify the user code of ZONE 1
In
relative passwords
ress the button to quit setting mode.
the setting mode:
Press the button and , the yellow LED indicator will be flashing,
then press the button and , a sound "BI" as reminder. Then input
(The length of
should as same as admin code).
P
three-figure 000 to 999 data storage units and input correlative passwords
Setting access control ID ( for RS-485 model VHA30N )
In
ress the button to quit setting mode.
the setting mode:
Press the button and , the yellow LED indicator will be flashing,
then press the button and , a sound "BI" as reminder. Then input
6 digits ID number, and a sound "BI" as reminder, means ID setting
successfully.
P
Group cards added in ZONE 1
In the setting mode:
Press the button and , the yellow LED indicator will be flashing,
then press the button and , a sound "BI" a reminder. Then input
three-figure 000 to 999 data storage units as start added unit, and input
3 digits number indicates the cards quantity you want to add in. For
example:
1. Input 005 060--means the cards added in storage units starting
from 005, and the quantity of the whole cards added in are 60.
2.
s
Input 060 150--means the cards added in storage units starting
from 060, and the quantity of the whole cards added in are 150.