background image

Operating instructions

TERRALOG

Summary of Contents for TERRALOG

Page 1: ...Operating instructions TERRALOG ...

Page 2: ......

Page 3: ...1 2 4 3 5 6 7 12 8 9 10 21 22 23 25 26 27 28 29 24 30 11 13 ...

Page 4: ......

Page 5: ... the prior written approval of the manufacturer Limitation of liability All technical information data and notes in these operating instructions regarding commissioning operation and maintenance are the most recent at the time of going to print The manufacturer assumes no liability for damage caused as a result of fail ing to follow the instructions improper use incorrect repairs unauthorised chan...

Page 6: ...voided it could result in injury Follow the instructions in this warning to avoid causing per sonal injury CAUTION A warning of this danger level indicates possible material damage If the situation is not avoided it could result in material damage Follow the instructions in this warning to avoid causing mate rial damage NOTE A note indicates additional infor mation to enable easier handling of the...

Page 7: ... by an author ised specialist workshop or by the factory service centre Repairs to the measurement device during the warranty period must be made by a service centre authorised by the manufacturer otherwise the warranty claim shall be invalid Defective components must be exchanged only for original replacement parts Only by using these parts can it be guaranteed that the safety requirements are me...

Page 8: ...h air and seek medical attention if you feel unwell The vapours could irritate the respiratory system CAUTION Possible material damage if batteries are used incorrectly Proceed in accordance with the fol lowing information to avoid material damage Use only the battery type ap proved by the manufacturer Remove leaking batteries im mediately from the measurement device Clean the contacts inside the ...

Page 9: ...ies 27 Vibraphone tripod and adapter disc 28 Lanyard 29 TERRALOG hand held device 30 Operating instructions Status bar see picture A 31 USB mode active 32 Bluetooth status 33 Filter active 34 Hearing protection active 35 Volume only displayed when the volume is changed Identification plate The identification plate 13 specifies the following information Type of measurement device Serial number Oper...

Page 10: ...hen not used it switches off automatically after 10 minutes Preparations Setting up the power supply The measurement device can be operated by means of disposable batteries rechargeable batteries For permissible types see Technical data CAUTION Damage to electronic components Incorrect setup of the power sup ply for the measurement device can cause damage to electronic components and other parts o...

Page 11: ...ton 7 Touch the vibraphone to test the function The smallest of vibra tions must be shown on the display Use Taking the measurement The monitoring procedure is used to isolate and pinpoint the leak site For structure borne sound meas urements place the vibraphone 25 on the measuring point under inspection pipe valve hydrant etc The noise level is shown on the display 10 Repeat the measurement at v...

Page 12: ...utton repeatedly The display switches between the setting options Off 63 Hz 100 Hz 160 Hz 250 Hz and 400 Hz Save the selected value by pressing and holding the button Change the low pass filter frequency C2 Select the desired frequency by pressing the button repeat edly The display switches between the setting options Off 4 kHz 2 5 kHz 1 6 kHz 1 kHz and 630 Hz Save the selected value by pressing a...

Page 13: ...e selected file by pressing and holding the button Press and hold the button to return to the menu D Settings E Bluetooth E1 For Bluetooth configuration see the section Bluetooth configuration on page 17 Hearing pro tection E2 To set the desired level of protec tion see the section Hearing protection on page 18 Date and time E3 To set the date and time see the section Setting the date and time on ...

Page 14: ...oth device Symbol flashing Waiting for connection Symbol lit Bluetooth error Restart both devices or recon nect as necessary Symbol flashing Bluetooth pairing is in progress General menu operation Once the measurement device is switched on the start screen main measurement A is dis played Pressing and holding the Menu button enables you to switch to the start screen at any time Pressing the Menu b...

Page 15: ...ones used are not the same as those used for the previous connection or if the headphones have been connected to another device then the measurement device and the headphones must be paired again To do this see the Connect ing headphones section Continuous measurement see picture D With continuous measurement up to 10 measured values can be deter mined and compared The minimum value from the measu...

Page 16: ...utton The ready to record display is shown Press and hold the Select but ton to start recording A progress bar for the recording the remaining recording time and the current measured value are displayed The recording symbol flashes To end the recording and create a file press the Select button When the memory is full the recording is stopped auto matically The file name is made up of the date and ...

Page 17: ...e Settings E menu and press the Select button The Bluetooth display E1 is shown Use the Select button to choose a Bluetooth function The functions are Switch on Bluetooth switch off Bluetooth pair headphones Press and hold the Select but ton to execute the selected function Once executed a tick will be displayed Switching on Bluetooth Bluetooth is switched on Once switched on the measurement devic...

Page 18: ...set When the hearing protection feature inter venes the volume is limited This is indicated by the hearing protection symbol 34 in the status bar The symbol goes out as soon as the volume drops below the set level of protection Setting the level of protection Use the Menu button to select the Settings E menu and press the Select button Use the Menu button to select the Hearing protection menu and ...

Page 19: ... accessories used with a damp cloth Switch off the measurement device and headphones Maintenance Visual checks during each use Check the measurement device and the accessories used for any signs of external damage Storage If you do not need the measurement device for an extended period clean it as described in the Cleaning sec tion Store the measurement device and all accessories in the transport ...

Page 20: ...isplay with 128 x 64 pixel resolution incl backlight contrast optimised for outdoor use Disposable rechargeable batteries 4 x alkaline AA LR6 or 4 x NiMH AA HR6 or 4 x zinc carbon AA R6 or 4 x lithium AA FR6 1 5 V 1 2 V 1 5 V 1 5 V Battery life Approx 50 hours with alkaline typically backlight off Bluetooth on Case Dimensions LxWxH 390 x 300 x 143 mm Total weight 4 6 kg Sensor Weight 600 g Headpho...

Page 21: ...s listed below Name of the measurement device TERRALOG hand held device Directives 2004 108 EC EMC Directive 1999 5 EC R TTE Directive Applicable standards DIN EN 61326 1 DIN EN 300 328 DIN EN 61010 1 Manufacturer vonRoll hydro oensingen AG vonRoll Strasse 24 CH 4702 Oensingen Switzerland __________________________ Frank Endress Managing Director Oensingen 1st June 2015 ...

Page 22: ...f Conformity 21 Equipment overview 9 G Ground spike 11 H Hearing protection 13 18 I Inserting batteries 10 Intended use 6 P Pairing the headphones 18 Playing back noises 13 R Reading files 17 Recording noises 12 16 S Safety 7 Scope of delivery 9 Setting the date 13 18 Setting the time 13 18 Setting the volume 14 Status bar 9 Storage 19 Switching off 10 Switching on 10 Switching the filter on and o...

Page 23: ......

Page 24: ...C A 31 32 33 34 B 51 41 42 44 43 D 35 ...

Page 25: ......

Page 26: ...vonRoll hydro suisse ag vonRoll Strasse 24 ch 4702 oensingen telephone 41 0 62 388 11 11 fax 41 0 62 388 11 78 info vonroll hydro ch www vonroll hydro ch A vonRoll infratec Group company ...

Reviews: