47
4
Check that the knob on the pressure test equipment
relief valve is unscrewed.
5
Connect the hose from the pressure test equipment
to the air terminal plate.
6
Lower the cylinder head into 70 degree water bath
and open the cock.
Repair Instructions
Cylinder head, leakage check
Special tools: 885 243, 885 274, 999 6662,
999 6532
WARNING! Pressure test equipment 999 6662
should be checked before use. Always follow
the safety precautions.
1
Connect the pressure test equipment to the pres-
surized air network and set the pressure gauge to
100 kPa (1 kp/cm
2
) with the relief valve.
NOTE! The relief valve knob can be locked with an
axially moved lock ring.
2
Then close the shut-off valve. To ensure that the
pressure test equipment is reliable the pressure read-
ing on the pressure gauge must not sink for 2 min-
utes.
3
Install the air terminal plate 999 6532 with four M8
screws and sealing plates 885 274 and 885 243 with
M10 nuts and appropriate spacer sleeves or cylinder
head screws.