Voltronic Power SCC-MPPT 300W Quick Manual Download Page 3

Terminal Installation 

Step 1: Prepare flat screwdriver, supplied terminals and   

stripped wires. 

 

 

Step 2: Insert stripped wire into supplied terminal.   

Use crimping tool to press stripped wire and terminal   

in position. Refer to chart2. 

 

Step 3: Screw assembled terminal and wire into solar 

charge controller. Refer to chart 3. 

Chart 3 

 

 

Mounting 

Step 1: Choose mounting location 

Locate the solar charger controller on a vertical surface.    Select an appropriate 

mounting location. Use a horizontal line and the length of the line must be 150mm 

and mark the two ends on the wall. (see Fig. 1 & Fig. 3) 

Step 2: Check the clearance   

Install the solar charge controller in a protected area that is free of excessive dust 

and has adequate air flow. Please place the solar charge controller away from other 

units at least 20 cm to avoid interference. Do NOT operate it where the temperature 

and humidity is outside the specific limits. (Please check the specs for the 

limitations.) 

Step 3: Drill the holes 

Remove the controller and drill 2 holes in the marked locations with 2 screws. 

Step 4: Secure controller 

Place the unit on the surface and align the mounting holes with 2 screws in step 3. 

(see Fig. 2 & Fig. 4) 

 

  Fig. 1          

  Fig. 2 

 

  Fig. 3          

  Fig. 4 

 

Wiring 

CAUTION! Be sure to secure all wiring, especially for mobile applications. Use 

cable clamps to prevent cables from swaying when the vehicle is in motion. 

Unsecured cables create loose and resistive connections which may cause excessive 

heating or fire 

 

Step 1: DC Load Wiring 

The load output will provide battery voltage to connected loads such as lights, 

pumps, monitors and other electronic devices. 

 

 

Step 1: connect load positive (+) wire to the positive terminal of the unit and load 

negative (-) wire to the negative terminal of the unit.   

Step 2: install a DC Breaker or a DC fuse holder in a positive wire. The rating of the 

DC Breaker/Fuse must be according to the charging current (40 Amp). Keep the DC 

Wall 

Chart 1 

Chart 2

 