Voltmaster TSP2 Owner'S Manual Download Page 13

Owner’s Manual

9

Voltmaster Trash Pumps

4

Troubleshooting

4.1

Common problems

For troubleshooting, check and resolve the following issues as needed. Contact the factory for 
assistance if necessary (see Section 1.2, 

Where to obtain service

, page 1).

If the pump fails to prime:

The priming chamber might be empty or not sufficiently full

Liquid in priming chamber might be overheated

The direction of rotation might be reversed

Rotation speed might be too slow

The impeller or volute might be worn or broken

Delivery line might be under pressure

There could be air leaks in the suction-line or at joints in the line, loose screws at joints in the line, 
or broken hoses in the line

There could be an air leak through a damaged mechanical seal

Quick-coupling gaskets might be broken or improperly mounted

Hose clamps might be loose or broken

If capacity is low:

The suction strainer might be clogged

The suction or delivery line might be obstructed

There could be high-friction losses in the suction line, which may require eliminating bends in 
the line or restrictions from valves

The suction lift could be too high

The rotation speed might be too slow

The impeller might be clogged

Summary of Contents for TSP2

Page 1: ...Voltmaster Trash Pumps Model TSP2 TSP3 and TSP4 Owner s Manual July 2010...

Page 2: ......

Page 3: ...y 3 2 2 Engine safety 4 2 2 1 Operator safety 4 2 2 2 California Proposition 65 5 2 2 3 Spark arresters 5 2 3 Storage and maintenance safety 5 3 Operation 7 3 1 Before starting 7 3 1 1 Safety 7 3 1 2...

Page 4: ...List of Figures Figure 4 1 Trash pump exploded view 10 List of Tables Table 4 1 Parts list for Model TSP2 2 inch trash pump 11 Table 4 2 Parts list for Model TSP3 3 inch trash pump 11 Table 4 3 Parts...

Page 5: ...ow all instructions carefully Read the engine manufacturer s instructions By following these instructions you will enjoy safe and trouble free operation of your trash pump 1 2 Where to obtain service...

Page 6: ...2 Owner s Manual Voltmaster Trash Pumps...

Page 7: ...serious health and environmental hazards Contact local authorities for assistance NEVER use pump with any safety guards removed NEVER leave the pump unattended while it is running Turn off engine when...

Page 8: ...ents to clean parts DANGER Asphyxiation hazard Engine exhaust contains carbon monoxide a poison gas you cannot see or smell NEVER operate indoors EVEN IF doors and windows are open Operate the engine...

Page 9: ...rain fuel Drain water and fluids that could freeze Drain fluids that contain solids that could settle or crystallize Drain fluids that may leave a solid or sticky residue inside the pump ALWAYS keep t...

Page 10: ...6 Owner s Manual Voltmaster Trash Pumps...

Page 11: ...red so that it cannot fall in Locate pump as close to the level of the fluid to be pumped but never higher than 25 feet 7 5m above fluid surface Keep hoses and piping straight and as short as possible...

Page 12: ...ugh the priming port on top of the pump DO NOT run pump dry Always fill the pump body with water before starting The pump is self priming when filled with water 4 Prepare for starting the engine a Obs...

Page 13: ...worn or broken Delivery line might be under pressure There could be air leaks in the suction line or at joints in the line loose screws at joints in the line or broken hoses in the line There could be...

Page 14: ...10 Owner s Manual Voltmaster Trash Pumps 4 2 Parts lists Figure 4 1 Trash pump exploded view...

Page 15: ...Discharge elbow 2 1 32 O ring 2 33 2 34 2 35 Suction strainer 2 1 36 Nut 4 37 Bolt 4 38 Roll cage assembly S 1 Table 4 2 Parts list for Model TSP3 3 inch trash pump Item Description Qty 1 Honda engin...

Page 16: ...er shim 0 030 x 1 1 12 O ring pump housing 1 13 Impeller 4 T CI 1 14 Volute 4 T CI 1 15 Volute gasket 4 1 16 Pump housing 4 1 17 Bolt 3 8 16 x 2 8 18 O ring drain filler plug 2 19 Drain filler plug 3...

Page 17: ......

Page 18: ...WANCO INC 5870 Tennyson Street Arvada Colorado 80003 800 972 0755 303 427 5700 303 427 5725 fax www voltmaster com 2010 Wanco Inc All rights reserved Printed in the USA part no rev...

Reviews: