background image

 

SBC-5925: 3 STAGE DC-DC CHARGER. 

DESIGNED TO CHARGE AUX BATTERIES WITH AND WITHOUT AN IGNITION TRIGGER.

 

NOTE:

 

BATCH STARTING WITH SERIAL#s G5016  

VEHICLES WITH A LOW VOLTAGE CHARGE ALTERNATOR WILL ONLY BE ABLE TO USE THE AUTO START MODE IF THE 
CHARGE VOLTAGE TO THE UNIT IS ABOVE 13.4V (START CHARGE = 13.4V (26.8V) STOP CHARGE = 12.8V (25.6V))

  

UNITS FROM THIS BATCH CAN STILL BE USED IF INPUT VOLTAGE IS < 13.4V BY USING THE IGNITION MODE 
 

NOTE:

 

BATCH STARTING WITH SERIAL#s 1516 

VEHICLES WITH A LOW VOLTAGE CHARGE ALTERNATOR CAN USE BOTH MODES. IF USING AUTO START MODE, CHARGE 
VOLTAGE SOURCE MUST BE ABOVE 12.8V (START CHARGE = 12.8V (25.8V) STOP CHARGE = 12.2V (24.6V)) 
 
10 SECOND DELAY FOR ALL SET POINTS FOR THIS BATCH. 

 
SPECIFICATIONS: 

 

9-32V input range (suitable for 12V or 24V input to 12V output but NOT 24V output): 

 

70 mA current draw on input side when not charging and unit on in AUTO START MODE. 

CHARGING STATUS LED  

 

 

BULK MODE 

(FAST FLASH): VOLTAGE WILL KEEP RISING UNTIL ABSORPTION VOLTAGE IS REACHED. 

 
SOFT START: 

(FAST FLASH): IF IN FLOAT, OUTPUT IS 1.15A UNTIL BULK CAN BE REACHED, THIS IS IF OUTPUT BATTERY IS 

LOW OR THERE IS A HIGH LOAD. 

 
ABSORPTION MODE 

(SLOW FLASH): VOLTAGE WILL STAY CONSTANT AT SET POINT AND CURRENT WILL DECREASE 

 
FLOAT MODE

 (SOLID): VOLTAGE IS CONSTANT, AND CURRENT IS MINIMAL 

 
LITHIUM FLOAT MODE

 (OFF): LITHIUM STOP CHARGE 

 

 

 

 

 

 

 

NOTE: FLOAT VOLTAGE ONLY FOR BATCH STARTING WITH SERIAL#s 1516 IS 0.5V LOWER THAN TABLE FIGURES 

Rated output power  20A at 13.8VDC 

Efficiency 

90% 

Output (Charge) Voltage 

Battery Type 

Absorption  Float 

Wet 

14.4 

13.3 

AGM 

14.3 

13.2 

GEL 

14.0 

12.9 

CAL 

15.1 

14.0 

LiFePO4 

14.8 

STOP 

Size (L x W x H) 

130 x 188 x 55mm 

Weight 

Approx. 870g 

Summary of Contents for SBC-5925

Page 1: ...32V input range suitable for 12V or 24V input to 12V output but NOT 24V output 70 mA current draw on input side when not charging and unit on in AUTO START MODE CHARGING STATUS LED BULK MODE FAST FLASH VOLTAGE WILL KEEP RISING UNTIL ABSORPTION VOLTAGE IS REACHED SOFT START FAST FLASH IF IN FLOAT OUTPUT IS 1 15A UNTIL BULK CAN BE REACHED THIS IS IF OUTPUT BATTERY IS LOW OR THERE IS A HIGH LOAD ABSO...

Page 2: ...both input and output to the unit 3 Unit can take input from either a 12V or 24V vehicle 4 Or you can take a Voltage signal 12V or 24V from any source 5 The unit will always start in bulk mode when connected or mode changed refer to Charging status LED 6 1 min delay for Start Charge 10 sec delay for Stop Charge in AUTO START MODE 10 sec delay in IGNITION MODE 7 IGNITION MODE ONLY Apply 9 32V to ig...

Page 3: ...N MODE or OK FOR VEHICLES 12 8V CHARGE OR OK FOR BATCH STARTING WITH SERIAL s 1516 IGNITION MODE 1 To change to IGNITION MODE supply 9 32V to the ignition pin at any time even in AUTO START MODE 2 There is no need to Press and hold the Battery Select button for this mode 3 THE SETTING IS SAVED UNTIL THE UNIT IS RESET TO AUTO START MODE TERMINAL BLOCK V IN The V pin has the same voltage as the inpu...

Page 4: ...d back on again Check charging status mode if solid green and output Voltage is higher than 12 6V Unit will be in float mode Load the output battery to check that current flows Check the input and output connections Check the input Voltage and compare to Start Charge setting and low Voltage Reconnect Check what mode the unit is in Unit may be in IGNITION MODE check if Input Voltage is above set po...

Page 5: ... keep the input Voltage above the Cut in setting see below for solution This is not a fault of the unit The unit starts in bulk mode AND input is below Cut out Voltage as the input and output are paralleled the overall input Voltage will drop depending on the charge source This is caused by either low voltage or low current input or very flat battery or high load on output Check input Voltage and ...

Reviews: