Charging Curve
Bulk:
This is the first charging stage where the battery at low charge stage, typically 10%, receives the majority of its
charge. During this stage the battery brought to about 95% of its charger getting 100% of the available solar power.
Pulse (Maintenance):
At the end of bulk stage, typically when the battery reach 14.4 Volts, a maintenance mode
starts where the battery voltage can float between an high and low value fixed by the controller. These values are
temperature compensated in order to keep the battery at 100% charge stage in any condition.
Protection functions
Overcharge
protection
Deep
discharge
protection
Battery
under
voltage
protection
Solar
panel
reverse
current
protection
The
following
installation
faults
do
not
destroy
the
controller.
After
correcting
fault,
the
device
will
continue
to
operate
correctly:
Overcharge
protection
Deep
discharge
protection
Reverse
polarity
protection
of
load,
panel
and
battery
Automatic
electronic
fuse
Short
circuit
protection
of
load
and
panel
Over
voltage
protection
at
panel
input
Open
circuit
protection
without
battery
Reverse
current
protection
at
night
Overload
protection
Battery
over
voltage
shutdown
Maintenance
The
controller
is
maintenance-free.
We
strong
suggest
that
all
components
of
the
PV
system
must
be
checked
at
least
annually,
Ensure
adequate
ventilation
of
the
cooling
element
Check
the
cable
strain
relief
Check
that
all
cable
connections
are
secure
Tighten
screws
if
necessary
Terminal
corrosion
5