3.4.
C
ONNECTING THE
S
AFETY
I
NTERLOCK
C
ABLE TO A
B
ANNER
L
IGHT
C
URTAIN
The following instruction has been written specifically for the BANNER EZ-Screen, Model
Number EZAC-R9-QE8 AC Interface Box
Caution:
Ensure that the light curtain and the AT5600 are disconnected from the mains supply line
before opening the control box. Failure to do so could result in personal injury.
Consult the user manual supplied with the light curtain for up-to-date information.
1) Voltech Safety Interlock Cable (250-030) preparation:
a) Cut the plastic tie-wrap joining the Blue wire and the Black jumper wire. The Black jumper
wire is not required for Banner Model Number EZAC-R9-QE8 installation.
Refer to Figure 1
Figure 1
b) Remove the Cable Gland supplied with the Safety Interlock Cable and replace with the cable
gland supplied with the Banner AC Interface Box. Do not tighten at this point. Refer to Figure 2.
Figure 2