11.  If the inverter is not properly operating, then refer to the troubleshooting 

sections of this manual. 

 

CAUTION:

 

Loose connectors may cause overheated wires and melted 

insulation.   

 

CONNECTION TO LOAD 

Plug the cord from the equipment you wish to operate into the AC receptacle. The 
green LED indicator lights to indicate that the inverter is functioning. Make sure 
the combined load requirement of your equipment does not exceed inverter’s 
output rating. 

The inverter is engineered to be connected directly to standard electrical and 
electronic equipment in the manner described above. Do not connect the power 
inverter to household or RV AC distribution wiring. Do not connect the power 
inverter to any AC load circuit in which the neutral conductor is connected to 
ground (earth) or to the negative of the DC (battery) source. 

WARNING:

  Do not connect to AC distribution wiring.  This inverter is NOT grid 

interactive. 

OPERATING ENVIRONMENT   

For best operating results, the inverter should be placed on flat surface, such as 
the ground, car floor, or other solid surface. The power cord allows easy 
positioning of the inverter. The inverter should only be used in locations that meet 
the following criteria: 

DRY

- Do not allow water and/or other liquids to come into contact with the power 

inverter.  In  all marine applications, do not install the inverter below or near the 
waterline and keep the inverter away from moisture or water. 

COOL

 – Ambient air temperature should be between 30 degrees F (-1 degree C) 

non-condensing, and 105 degrees F (40 degrees C). Do not place the inverter on 
or near a heating vent or any piece of equipment which is generating heat above 
room temperature. Keep the inverter away from direct sunlight, if at all possible. 

VENTILATED

 – Keep the area surrounding the inverter clear to ensure free air 

circulation around the unit. Do not place items on or over the inverter during 
operation. A fan is helpful if the inverter is operating at maximum power outputs for 
extended periods of time.  The unit will shut down if the internal temperature 
exceeds operating temperatures. The unit will restart after it cools. 

 

Summary of Contents for Pure Sine Wave

Page 1: ...RE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE IMPORTANT SAFETY INSTRUCTIONS To ensure reliable service your power inverter must be installed and used properly Please read the installation and operating instructions thoroughly prior to installation and use Pay particular attention to the WARNING and CAUTION statements in this manual The CAUTION statements advise against certain conditio...

Page 2: ...se permanent damage to the inverter 2 This inverter will not operate high wattage appliances over the output power limit or surge power limit 3 Grounding the neutral will cause the inverter to shut down Do not operate this inverter if it is wet Do not install in engine compartment please install in a well ventilated area 4 This inverter is not tested for use with medical devices IMPORTANT CABLE IN...

Page 3: ...dge configuration THE OUTPUT WAVEFORM The AC output waveform of the inverter is known as Pure Sine Wave or True Sine Wave It is a waveform that has characteristics same to the sine wave shape of utility power See Figure 1 FIGURE 1 Pure Sine Wave Waveform INSTALLATION ENVIRONMENTS POWER SOURCE REQUIREMENTS The power source must provide between 10 5 and 15 5 volts DC and must be able to supply the n...

Page 4: ...te flammable gas during charging or discharging The inverter has four slots in its mounting bracket that allow the unit to be fastened against a bulkhead floor wall or other flat surface Ideally the mounting surface should be cool to the touch It is more electrically efficient to use longer AC wiring than DC wiring so install the inverter as close as possible to the 12 VDC power source The inverte...

Page 5: ...Install a fuse holder or breaker close to the positive terminal of the DC source battery 4 Connect a length of wire on one side of the fuse holder or circuit breaker Connect the other end if the wire to the positive terminal of the inverter 5 Connect a length of wire between the inverter s negative terminal and the DC power source negative terminal 6 Connect a short length of wire to the other ter...

Page 6: ...ults the inverter should be placed on flat surface such as the ground car floor or other solid surface The power cord allows easy positioning of the inverter The inverter should only be used in locations that meet the following criteria DRY Do not allow water and or other liquids to come into contact with the power inverter In all marine applications do not install the inverter below or near the w...

Page 7: ...ome televisions may require 2 to 6 times their wattage rating to start up The most demanding in this category are those that start under load such as compressors and pumps To restart the unit after a shutdown due to overloading remove the overload if necessary turn the power switch OFF then ON DETERMINING BATTERY SIZE The power inverter will require DEEP CYCLE lead acid batteries of appropriate ca...

Page 8: ...W BATTERY VOLTAGE PROTECTION This condition is not harmful to the inverter but could damage the power source The inverter automatically shuts down when input voltage drops to 10 5 volts OVER VOLTAGE PROTECTION The inverter will automatically shut down when the input voltage exceeds 15 0 volts DC Input voltage exceeds 16 volts could damage the inverter OVERLOAD PROTECTION The inverter will automati...

Page 9: ...being connected to or disconnected from the power source This is not indicative of a problem SPECIAL FEATURES USB port Remote Control port No of AC Outlet DC Terminal Cover SMART FAN 350W YES NO 2 NO YES 600W YES NO 2 NO YES 1000W NO YES 2 YES YES 1500W NO YES 2 YES YES 2000W NO YES 2 YES YES Standard USB charging port 5Vdc 500mA Compatible with specify Voltec remote control only Connect with inco...

Page 10: ...lit Green LED not lit Inverter shut down by overload surge earth fault protection circuit Unplug the faulted load and wait 2 mins for inverter to cool For models with GFCI only No AC output latch up Red LED not lit Green LED lit Inverter shut down by ground fault Remove the ground faulted AC load and reset the unit Low battery alarm sounds abnormal Bad connection or wiring Tighten all DC connectio...

Page 11: ...m occurs Please DO NOT replace the fuse yourself we recommend you contact technician to find and fix the problems High voltage and high temperature inside CAUTION NO USER SERVICEABLE COMPONENTS INSIDE DO NOT ATTEMPT TO OPEN THE INVERTER SPECIFICATIONS Output Connection North America AC Receptacle s Output Voltage Approx 115 volt AC RMS 60 Hz Output Waveform Soft Start Pure Sine Wave Max Efficiency...

Reviews: