Voltdrive voltguard portguard User Manual Download Page 5

VOLTDRIVE s.r.o.,

Háj 365 (MICOS TELCOM premises), 798 12 Kralice na Hané, Czech Republic

Tel.: +420 582 307 603, Fax: +420  582 307 688

e-mail: [email protected], www.voltdrive.com

5

RELEASE 0 – input voltage (0÷3 V) 

PUSH BUTTON 0 – input voltage (0÷3 V)

RELEASE 1 – input voltage (12÷24 V) 

PUSH BUTTON 1 – input voltage (12÷24 V)

Summary of Contents for voltguard portguard

Page 1: ...ibution meter The communication between the HomeGuard residual capacity meter and the PortGuard charging control unit can also be done by means of RS485 twisted pair bus however such a cable is usuall...

Page 2: ...the status machine are described in the status diagram see below CHARGING PROCESS The input pin Terminal 16 PB PUSH BUTTON controls locking unlocking of the charging cable socket The PB input voltage...

Page 3: ...cle corresponding to magnitude of the charging current In case the voltage drop on the pin Terminal 5 CP is 6V or 3V the device goes into the WAIT 3 sec mode In case the voltage detected on the pin Te...

Page 4: ...minal 17 weight 2 input Terminal 17 weight 4 similar to binary to decimal conversion If the voltage detected on the particular input Terminal 17 18 19 is within 0 3 V the weight of the particular inpu...

Page 5: ...12 Kralice na Han Czech Republic Tel 420 582 307 603 Fax 420 582 307 688 e mail info voltdrive com www voltdrive com 5 RELEASE 0 input voltage 0 3 V PUSH BUTTON 0 input voltage 0 3 V RELEASE 1 input v...

Page 6: ...the socket lock switch closed Terminal 4 The locked socket state switch this pin is used for delivering the signal GND for the socket lock switch Terminal 5 The CP input output on this pin the microp...

Page 7: ...with a rated voltage of 12 V 1 A a lower power source may not fully cover the device demands in all operating modes a higher power source may dam age the motor output control in case of short circuit...

Page 8: ...version CON4 Connector KONFIG installed inside the device The device configuration connector As shown in the diagram above the installed jumper enables the configuration of the device according to th...

Page 9: ...s free capacity 12 3 A SUMA the control packet sum the result is one byte and it is calculated as XOR of all bytes over the SUMA byte including the STX byte TYPE DESIGNATION AND ORDER CODE PortGuard P...

Page 10: ...ation Switching relay output contacts for error mode indication LEI status indicator output Input output for controlling the motor of the charging cable socket lock Construction parameters Dimensions...

Page 11: ...t not be operated with other voltage current or frequency than it was produce or professionally modified for The product must be placed and secured so that it is difficult to access or inaccessible fo...