PortGuard

USER MANUAL

BASIC PURPOSE

PortGuard is an electric vehicle charging control unit 
communicating with electric vehicles in accordance 
with the CNS EN 61851-1 standard. This unit is 
installed in electric vehicle charging stations, usually 
for Mennekes Type 2 sockets. The PortGuard charging 
control unit is used for setting the required charging 
station parameters, indicating the charging station 
status and checking the service and additional 
devices to ensure safe charging of electric vehicles.
When installed within the VoltGuard charging 
infrastructure system, the PortGuard charging control 
unit is used as the final action element of the electric 
vehicle charging system processing information 
transferred from the HomeGuard residual capacity 
meter through the serial line and dynamically setting 
the consumption parameters. It is capable of setting 
the charging current exactly according to the current 
available at the point of supply (at the distribution 
meter). The communication between the HomeGuard 
residual capacity meter and the PortGuard charging 
control unit can also be done by means of RS485 twisted pair bus, however, such a cable is usually not installed 
between the input of the power supply point and the charging station. In case the installation uses the ShiftGuard PLC 
modems, the charging stations can be placed anywhere after the distribution meter. 

MAIN FEATURES

¬

  Electric vehicle charging control in accordance with the CNS EN 61851-1 standard

¬

  Power supply of 230V AC and for controlling the armature of the power contactor of the electric vehicle power supply line

¬

  CC (Current Configuration) inputs for entering the maximum electric vehicle charging current evaluated throughout 

the charging process

¬

  Evaluation of the type of the connected PP charging cable using point-to-point resistance (RPP)

¬

  Switching relay contact outputs for activating the ventilation

¬

  Switching relay contact outputs for signalling the error status

¬

  Outputs for LED status indication

¬

  Circuits for controlling the motor of the charging cable socket lock, monitoring its proper locking

¬

  Automatic unlocking of the socket in case of 230V AC power failure

¬

  DC power supply (12V / 0.85A) output terminals for other purposes

¬

  Communication interface RS-485 (semi-duplex, 9600 Bd, 8N1)

¬

  Dimensions designed for MODULBOX 5M

Summary of Contents for voltguard portguard

Page 1: ...ibution meter The communication between the HomeGuard residual capacity meter and the PortGuard charging control unit can also be done by means of RS485 twisted pair bus however such a cable is usuall...

Page 2: ...the status machine are described in the status diagram see below CHARGING PROCESS The input pin Terminal 16 PB PUSH BUTTON controls locking unlocking of the charging cable socket The PB input voltage...

Page 3: ...cle corresponding to magnitude of the charging current In case the voltage drop on the pin Terminal 5 CP is 6V or 3V the device goes into the WAIT 3 sec mode In case the voltage detected on the pin Te...

Page 4: ...minal 17 weight 2 input Terminal 17 weight 4 similar to binary to decimal conversion If the voltage detected on the particular input Terminal 17 18 19 is within 0 3 V the weight of the particular inpu...

Page 5: ...12 Kralice na Han Czech Republic Tel 420 582 307 603 Fax 420 582 307 688 e mail info voltdrive com www voltdrive com 5 RELEASE 0 input voltage 0 3 V PUSH BUTTON 0 input voltage 0 3 V RELEASE 1 input v...

Page 6: ...the socket lock switch closed Terminal 4 The locked socket state switch this pin is used for delivering the signal GND for the socket lock switch Terminal 5 The CP input output on this pin the microp...

Page 7: ...with a rated voltage of 12 V 1 A a lower power source may not fully cover the device demands in all operating modes a higher power source may dam age the motor output control in case of short circuit...

Page 8: ...version CON4 Connector KONFIG installed inside the device The device configuration connector As shown in the diagram above the installed jumper enables the configuration of the device according to th...

Page 9: ...s free capacity 12 3 A SUMA the control packet sum the result is one byte and it is calculated as XOR of all bytes over the SUMA byte including the STX byte TYPE DESIGNATION AND ORDER CODE PortGuard P...

Page 10: ...ation Switching relay output contacts for error mode indication LEI status indicator output Input output for controlling the motor of the charging cable socket lock Construction parameters Dimensions...

Page 11: ...t not be operated with other voltage current or frequency than it was produce or professionally modified for The product must be placed and secured so that it is difficult to access or inaccessible fo...