![VOLTCRAFT VC-335 Operating Instructions Manual Download Page 49](http://html1.mh-extra.com/html/voltcraft/vc-335/vc-335_operating-instructions-manual_1047254049.webp)
49
Direct current
Range
Resolution
Accuracy
20.00 A
0.01 A
± (2 % + 3)
200.0 A
0.1 A
± (2 % + 3)
Overload protection: 200 A
DC accuracy: After successful zero adjustment
AC voltage
Range
Resolution
Accuracy
2.000 V
0.001 V
± (1.0 % + 3)
20.00 V
0.01 V
200.0 V
0.1 V
± (1.0 % + 3)
600 V
1 V
± (1.2 % + 3)
Frequency range: 45 - 400 Hz; Overload protection: 600 V; Impedance: 10 MΩ
Crest Factor (CF)
CF 1.0 - 2.0: + 3 % deviation
CF 2.0 - 2.5: + 5 % deviation
CF 2.5 - 3.0: + 7 % deviation
DC voltage
Range
Resolution
Accuracy
200.0 mV
0.1 mV
± (1 % + 8)
2.000 V
0.001 V
± (0.7 % + 3)
20.00 V
0.01 V
200.0 V
0.1 V
600 V
1 V
Overload protection: 600 V; Impedance: 10 MΩ