61
Direct current (DC)
Range Resolution:
Accuracy
400 µA
0.1 µA
4000 µA
1 µA
±(1,2% + 2)
40 mA
0.01 mA
400 mA
0.1 mA
±(1,5% + 2)
10 A
0.01 A
±(2,2% + 5)
Other Features
Overload protection: Fuses;500 mA 660 V, 10 A 600 V ;
Measuring time limit > 5 A: max. 30 s with
15 min break
Alternate current (AC)
Range Resolution:
Accuracy
400 µA
0.1 µA
4000 µA
1 µA
±(1,5% + 3)
40 mA
0.01 mA
400 mA
0.1 mA
±(1,8% + 3)
10 A
0.01 A
±(2,2% + 6)
Other Features
Overload protection: Fuses;500 mA 660 V, 10 A 600 V ;
Measuring time limit > 5 A: max. 30 s with
15 min break; frequency range 50 - 400 Hz
Resistance
Range Resolution:
Accuracy
400 Ω
0.1 Ω
±(1,8% + 5)
4 kΩ
0.001 kΩ
40 kΩ
0.01 kΩ
±(1,5% + 2)
400 kΩ
0.1 kΩ
4 MΩ
0.001 MΩ
±(2,0% + 2)
40 MΩ
0.01 MΩ
±(2,5% + 2)
Other Features
Overload protection 600V;
Measuring voltage: approx. 0.28 V