INTENDED USE

Analogue  fixed  measuring  instruments  are  intended  for  installation  in  switching  cabinets  or 

display panels. The installation occurs directly without external components; appropriate pre-

resistors are already integrated in the circuit. Only in integrated status they may be put into 

operation. The suitable regulations are to be observed. The fixed measuring instruments are 

available with different measurement ranges. The scale needle can be adjusted precisely 

with  the  front  screw.  The  fixed  measuring  instrument  may  only  be  used  in  voltage  ranges  

<75 V/DC. Observe the technical data for this! Assembly and installation may only be carried out 

by a specialist, who is familiar with the relevant regulations and the ensuing risks.
The device must not be used in damp interiors or outdoors in the open air.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use 

the product for purposes other than those described above, the product may be damaged. 

In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc. 

Read the instructions carefully and keep them. Make this product available to third parties only 

together with its operating instructions.
This product complies with the statutory national and European requirements. All company 

names and product names are trademarks of their respective owners. All rights reserved.

DELIVERY CONTENT

•  Meter
•  Mounting material
•  Operating instructions

SAFETY INSTRUCTIONS

Read the operating instructions carefully and especially observe the safety 

information. If you do not follow the safety instructions and information 

on proper handling in this manual, we assume no liability for any resulting 

personal injury or damage to property. Such cases will invalidate the warranty/

guarantee.
a) Persons / Product
•  The fixed measuring instrument must not be used for medical purposes.
•  Be especially cautious in dealing with voltage >35 V/DC. Already at this voltage you 

can get a life-threatening electric shock when touching electric lines.

•  The device is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. These may become 

dangerous playing material for children.

•  Protect the product from extreme temperatures, direct sunlight, strong jolts, high 

humidity, moisture, flammable gases, vapours and solvents.

•  Do not place the product under any mechanical stress.
•  If it is no longer possible to operate the product safely, take it out of operation and 

protect it from any accidental use. Safe operation can no longer be guaranteed if 

the product:

 - is visibly damaged, 
 - is no longer working properly, 
 - has been stored for extended periods in poor ambient conditions or 
 - has been subjected to any serious transport-related stresses.

•  Please handle the product carefully. Jolts, impacts or a fall even from a low height 

can damage the product.

•  Also observe the safety and operating instructions of any other devices which are 

connected to the product.

•  De-energise the electric system before installing the measuring instrument.
b) Miscellaneous
•  Consult an expert when in doubt about operation, safety or connection of the 

device.

•  Maintenance,  modifications  and  repairs  are  to  be  performed  exclusively  by  an 

expert or at a qualified shop.

 Legal notice

These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7  

(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing 

systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.

© Copyright 2013 by Voltcraft®

If you are not sure about the correct connection or use, or if questions arise which are not 

covered by these operating instructions, please do not hesitate to contact our technical support 

or another qualified specialist.
Voltcraft®, Lindenweg 15, D-92242 Hirschau, Tel. +49 180/586 582 7.

EXPLANATIONS OF SYMBOLS

At the scale’s face different symbols are attached, that have the following significance:

  Installation position vertical

2.0

Accuracy class related to the scale 

end value

Direct voltage/-current (DC)

Moving coil instrument

INSTALLATION

Mount the measuring instrument with the assembly material included in a pre-assembled 

rectangular front panel opening. Carefully attach the fixed measuring instrument. You can get 

the corresponding dimensions (in mm) from the following sketch. 

85.5

64.5

9.3 11.0

11.0

44.5

ø45.0

ø 3.0

ø 3.0

ø 3.0

ø 3.0

43.5

18.0

CONNECTION

In order to ensure a correct start of operation, you should read these operating 

instructions including the safety instructions thoroughly and attentively before 

using the device.
Do not connect when the wires are live.

Connection of the voltage measuring instruments (item no. 103075 and 103076) is done by 

means of parallel connection. Connection of the current measuring instruments (item no. 

103073 and 103074) is done by means of series connection. Connect the fixed measuring 

instrument to the two screw terminals on the back as shown.
Parallel connection for V  

 

         Series connection for A

DISPOSAL

Electronic devices are recyclable waste and must not be disposed of in the household 

waste.
At the end of its service life, dispose of the product according to the relevant statutory 

regulations.

TECHNICAL DATA

Item no.:

10 30 73

10 30 74

10 30 75

10 30 76

Measurement range: 5 A/DC

15 A/DC

15 V/DC

30 V/DC

Accuracy class:

2.0

Movement:

Moving coil

Operating conditions:

-25 to +55 °C, 20 – 95% RH

Storage conditions:

-40 to +70 °C, 20 – 95% RH

Weight:

approx. 65 g

Summary of Contents for AM-86X65

Page 1: ...rodukt sichtbare Schäden aufweist nicht mehr ordnungsgemäß funktioniert über einen längeren Zeitraum unter ungünstigen Umgebungsbedingungen gelagert wurde oder erheblichen Transportbelastungen ausgesetzt wurde Gehen Sie vorsichtig mit dem Produkt um Durch Stöße Schläge oder dem Fall aus bereits geringer Höhe wird es beschädigt Beachten Sie auch die Sicherheitshinweise und Bedienungsanleitungen der...

Page 2: ...periods in poor ambient conditions or has been subjected to any serious transport related stresses Please handle the product carefully Jolts impacts or a fall even from a low height can damage the product Also observe the safety and operating instructions of any other devices which are connected to the product De energise the electric system before installing the measuring instrument b Miscellaneo...

Page 3: ...oute sécurité n est plus garantie si le produit présente des traces de dommages visibles le produit ne fonctionne plus comme il devrait a été stocké pour une période prolongée dans des conditions défavorables ou bien a été transporté dans des conditions très rudes Maniez le produit avec précaution À la suite de chocs de coups ou de chutes même de faible hauteur l appareil peut être endommagé Respe...

Page 4: ...wanneer het product zichtbaar is beschadigd niet langer op juiste wijze werkt tijdens lange periode is opgeslagen onder slechte omstandigheden of onderhevig is geweest aan ernstige vervoergerelateerde druk Behandel het product met zorg Schokken botsingen of zelfs een val van een beperkte hoogte kan het product beschadigen Neem alstublieft ook de veiligheids en gebruiksaanwijzingen van alle andere ...

Reviews: