Voltacon VMI500 Quick Installation Manual Download Page 2

LED

DC Connector

AC Connector

Please Confirm Before Connecting the 

VOLTACON

 Microinverter

1. Whether the grid voltage at the common connection point conforms to the AC voltage level 

on the micro-inverter label.

2. Whether the electrical parameters of the PV modules meet the DC input range on the 

microinverter label.

Installation Steps

VMI

550 Installation and Connection Diagram

Step 1: Install the LCF Filter Used to Eliminate PLCC Communication Interference

 (Skip When There is No Monitoring Device)

Select a suitable AC cable to connect the LCF to the power distribution box or AC outlet, pay 
attention to the current carrying capacity of the AC cable, and must adapt to the total output 
current of all microinverters connected to the filter. For example, when there are 2 
microinverters, the cable carrying capacity must be greater than 5A, and when there are 8 
microinverters, the cable carrying capacity must be greater than 20A. A 10AWG cable is 
recommended.

Note

If

 

the

 

number

 

of

 

connected

 

microinverters

 

is

 

more

 

than

 

8

 

you

 

need

 

to

 

connect

 

another

 

AC

 

bus,

 

and

 

then

 

add

 

LCF

 

filters,

 

monitoring

 

equipment

 

EMU

 

and

 

other

 

related

 

accessories

 

according

 

to

 

requirements

.

,

LC Filter

AC

Grid Distribution Box

/Outlet

Step 2: Install the Monitoring Device EMU (Skip If There is No Monitoring Device)

a. Connect L and N of EMU to LCF filter, and pay attention to the polarity of L and N.
NOTE: The connection must be on the side away from the distribution box or outlet.

b. Connect the network cable (RJ45 cable) of the EMU to the LAN port of the router that can 
directly access the Internet.

LC Filter AC

Grid Distribution Box

/Outlet

Ethernet Router

EMU

c

 

2022 

 VOLTACON