Voltacon 48100B User Manual Download Page 10

1.2 BMS function 

Protection and Alarm 

Management and Monitor 

Charge/Discharge End 

Cell Balance 

Charging over Voltage 

Intelligent Charge Model 

Charge/Discharge Over Current 

Charge/Discharge current Limit 

High/Low Temperature 

Capacity Retention Calculation 

Short Circuit 

Administrator Monitor 

Power Cable Reverse 

Record 

2 Interface and protection functions 

2.1 Battery front panel schematic 

2.2 Components 

No. 

Name 

Label 

Functions description 

Ground 

Grounding 

Power button 

POWER 

When switched to "ON", the system 

can be activated by the "SW" key or 

external power supply; when switched 

to "OFF", the system is off. 

Voltacon 5.12kWh Lithium Battery User Manual 

Summary of Contents for 48100B

Page 1: ...V2 0 User Manual Lithium Ion Battery 48V 50Ah 100Ah 48100B 4850B...

Page 2: ...install and perform maintenance on the LFP battery pack The boundaries of its use as described in this manual should be kept in mind This LFP battery pack may not be used in medical or in aviation rel...

Page 3: ...regulations 1 Do not dispose of batteries in fire The batteries may explode 2 Do not open or mutilate batteries Released electrolyte can prove harmful to the skin and eyes It may be toxic 3 A battery...

Page 4: ...or DLG authorized technical engineers System failure caused by such will not be covered by the warranty Danger e Wear personal protective equipment f Ensure that if the battery is either intentionally...

Page 5: ...gh short circuit current do not short circuit the Li ion battery caution do not dispose the product with household wastes danger keep the Li ion battery away from water dust and contamination otherwis...

Page 6: ...transportation storage requirements 11 4 1 Transportation 11 4 2 Storage 11 5 Installation and configuration 12 5 1 Installation preparation 12 5 2 Unpacking 13 5 3 The preparatory work 14 5 4 Install...

Page 7: ...6 7 4 ALM constantly on 22 Voltacon 5 12kWh Lithium Battery User Manual...

Page 8: ...L440mm W620mm H117mm 2 6U Unit Weight 25kg 50 6kg 51kg Standard Charge Discharge Current 25A 50A 50A Maximum Charge Discharge Current 50A 100A 100A Peak Current 102A 15s 102A 15s 102A 15s Round Trip...

Page 9: ...0 25 C 1 1 Product standard configuration Items Quantity Specifications Pictures E BOX SERIES 1pcs LFP pack including BMS three interfaces CAN RS 485 RS232 2 Link ports LED power indicator and insulat...

Page 10: ...Capacity Retention Calculation Short Circuit Administrator Monitor Power Cable Reverse Record 2 Interface and protection functions 2 1 Battery front panel schematic 2 2 Components No Name Label Functi...

Page 11: ...ator CHARGE A total of 6 green lights showing battery capacity each representing 16 7 of SOC 6 External CAN communication port CAN Communication with external devices 7 External RS 485 communication p...

Page 12: ...lations before transporting an LFP battery During the transportation protect the battery from severe vibration shock or squeeze and from exposure to the sunlight and rain During the loading and unload...

Page 13: ...ion 5 1 1 Safety Requirements Only those who have been trained in the power system and have a good knowledge of the power system are allowed to install the device Always observe local safety regulatio...

Page 14: ...ing interface of the energy storage inverter meets the charging voltage and current requirements in Table 1 1 Battery Pack Specifications Whether the power of the electrical equipment matches the para...

Page 15: ...All power supply should be off 5 4 Installation 5 4 1 Install the battery The E BOX SERIES can be installed either vertically or horizontally In this chapter instructions here are only for horizontal...

Page 16: ...based on your load by referencing to the table below AWG Area Standard Current Max Current kcmil mm A A 4 41 7 21 15 83 5 95 2 5 33 1 16 77 66 2 75 5 6 26 3 13 3 52 5 59 9 7 20 8 10 55 41 6 47 5 8 16...

Page 17: ...f BMS and power cable we supply only two batteries can be connected in parallel and a bus bar should be used for connecting them together Warning Batteries connected in series are forbidden high volta...

Page 18: ...e host and the slave communicate in cascade mode one is the host and the rest are the slaves Please refer to the following picture for the cascade connection User needs to insert communication cables...

Page 19: ...ame time Standby Normal Blink 1 OFF OFF OFF OFF OFF OFF OFF Indication standby Alarm OFF Blink 3 OFF OFF OFF OFF OFF OFF Battery low voltage Charging Normal Light OFF Base on capacity Alarm Light Blin...

Page 20: ...inal RJ45 port follow RS485 protocol to output batteries information RS232 RS232 Communication Terminal RJ45 port follow RS232 protocol to upgrade the software and communicate with your PC Link Port 0...

Page 21: ...ethods mentioned below Please read the Table 5 3 LED indication of this manual before troubleshooting to prevent false operations For example it doesn t indicate the battery is faulty if the ALM alarm...

Page 22: ...2 Unable to charge Problem Troubleshooting Steps Solution The unfully charged battery cannot be charged properly 1 Confirm that the battery is turned on 2 Check the power cable Confirm that the power...

Page 23: ...or is constantly red and the other indicators are off the battery is in the Protection state When the condition triggered protection is released the battery will automatically return to normal operati...

Page 24: ...Battery quantity Inverter quantity Purchase date Inverter using time Serial number on grid off grid Installer name Installing date Photos of inverter wiring and panels Photos of battery wiring Email W...

Page 25: ...24 VOLTACON UK LIMITED Burnsall Road Canley Industrial Est CV5 6BU UK 44 2477 675 575 INFO VOLTACON COM Voltacon 5 12kWh Lithium Battery User Manual...

Page 26: ...25 All Rights Reserved Voltacon 2022...