Owner’s Manual #513685
6
U421 I2 Model Machines
When Using Bag Connection System (BCS) with One
or Two Bags (optional kit #2183987):
When connecting one or two bags, the manifold adapt-
ers must be installed closest to the manifold outlet and
the manifold plug(s) must be placed farthest from the
manifold outlet.
1.
Connect 3/8” (9,5mm) ID plastic food grade tubing
to a bag adapter. Secure with hose clamps.
2.
Slide the hose clip over the free end of the tubing.
Attach the free end of the tubing to a manifold
adapter. Secure with a large hose clamp.
3.
Push the manifold adapter with spring and valve
into the left port (nearest the manifold outlet) of
the mix inlet manifold and secure with retaining
clip. (See Figure 2-4).
4.
If using two mix bags, repeat steps 1 to 3 for the
middle port.
5.
Install a manifold plug into each empty inlet and
secure with a retaining clip.
6.
Place the mix bag(s) into
the mix container.
7.
Connect the bag adapter
attached to the left side
of the manifold (closest
to the mix outlet) to the
mix bag in the back of
the mix container.
Figure 2-4 Bag Connection System (Optional)
Bag Adapter
Manifold
Adapter
Retaining
Clip
Mix Inlet
Manifold
Manifold
Plug
2.6 INTELLITEC2™ SETUP
A.
Disassemble, clean, lubricate and assemble the
machine following the steps in Section 3.
B.
Fill the mix containers in the cabinet with sanitizer.
C.
Connect power to the machine and press the
Main Power On/Off button.
NOTE
The Current Status screen should show “Calibra-
tion Required” for both cylinders. If it does not, go
to the Unit Calibration option in the Utilities menu
to complete the calibration.
D.
Press the Pump On/Off button when the Current
Status screen is displayed.