6
FlexVent™ Versatile Slide-In with Downdraft Vent System and Fire Suppression Operator’s Manual
Remove Filters
1.
Turn off the electrical cooking appliances.
2.
Touch
to turn the unit off.
3.
Lift the Grease Filters up, pull the bottom forward, then
down and out.
4.
Lift the Drip Tray straight up to remove it.
5.
Lift the Particulate Filters straight up to remove them.
6.
Replace filters in reverse order.
NOTE: Ensure the Particulate Filters are properly oriented per
the label.
A. Grease Filters (2) 352035-2
B. Drip Tray 352034-2
C. Particulate Filters (2) 352010-1
A
B
C
System Cleaning and Maintenance
Procedure
Inspected
System Cleaning
Monthly Interlock System
Test
Quarterly Plenum Cleaning
Fire Suppression System
Maintenance
Semi-Annual Fire
Suppression Inspection &
Maintenance
Annual Fire Suppression
System Inspection &
Maintenance
12-Year Fire Suppression
System Inspection &
Maintenance
Maintenance & Service Log