6
Down Draft Vent Module with Induction Range(s) Operator’s Manual
DOWNDRAFT VENT OPERATION (CONTINUED)
Maintenance
Particulate Filter Replacement
NOTICE: Replace filters every six months or sooner if they become clogged.
1. Remove the grease filters to access the particulate filters.
2. To install a replacement filter, note the air flow direction arrow on the
particulate filter. Position the filter so the airflow arrow points down.
3. Place the filter into the base of the downdraft vent shroud.
4. Re-install the grease filters.
Troubleshooting
Particulate
filter
Problem
Might be Caused By
Course of Action
Downdraft Vent Module will not
operate. Main Power light is not
illuminated.
No power.
• Reconnect to electrical power.
• Reset circuit breaker for unit.
• Contact Vollrath Technical Services.
ANSUL Fire Suppression System not
properly commissioned or in need of
service.
Contact an authorized ANSUL representative for repair.
Low indicator light illuminated and
cooking unit will not turn on.
Particulate or grease filters not in
position, missing or incorrect type.
Properly install correct filters.
High indicator light illuminated and
cooking unit will not turn on.
Particulate or grease filters dirty or
incorrect type.
Install correct clean filters.