Vollrath 26806 Operator'S Manual Download Page 2

C

ountertop

 W

arming

 

and

 d

isplay

O

peratOr

s

 M

anual

 2

U

npacking

 

the

 e

qUipment

 

and

 i

nitial

 S

etUp

When no longer needed, dispose of all packaging and materials in an 

environmentally responsible manner. Have the unit installed only by qualified 

service personnel. This unit must be installed in accordance with any local 

and national plumbing codes.  

 

„

A shut-off valve to control the fresh water supply to this product is 

required.  

 

„

This unit requires a 120Volt 15Amp electrical outlet.

 

„

Units using this auto-fill unit MUST NOT SHARE A DRAIN LINE with 

any other units that do not have the same well depth.

 

„

Multiple units with the same well depth may share a drain line provided 

they are level to each other within ¼”.

 

„

Maximum water pressure is 80 PSI.

NOTE

: A water filter to remove particles that may clog the solenoid valve is 

strongly recommended. 
1.  Remove all packing material and tape, as well as any protective plastic 

from the equipment.

2.  Clean any glue residue left over from the plastic or tape.
3.  If installing this Auto-fill on a Vollrath drain manifold, cut off the pipe cap 

from the end of the drain manifold assembly that is on the opposite end 

of the main drain valve.

4.  Solder the Auto-Fill manifold assembly (A) to the open end of the drain 

line (B) from step 2 making sure the auto fill manifold is level with the 

existing drain manifold. Figure 1.

D

C

B

A

Figure 1. Drain Line and Manifold Assembly .
5.  For installation with Rectangular Drop-In 
For initial setup, mount the 

Auto-Fill main body water reservoir (B) level to the bottom of any full size 

Vollrath hot well (C) unit outer skin. Mark and use appropriate length 

fasteners to mount reservoir (B) assembly in a level position (D) to the 

bottom of the well assembly (A). See Figure 2.

6.  For use with Round Soup Drop-In: Install the reservoir (B) 5/8” 

(15 mm) below the bottom of a Vollrath round soup drop in unit outer 

skin. See Figure 2.

1.  The adjustment procedure above should be used with soup pots with 

the understanding that the water level the unit will maintain is the water 

level when there is a soup pot in use. The recommended 5/8” (15 mm)” 

placement of the reservoir below the soup warmer (In the installation 

section above) will maintain water at the water level mark in the well. 

However at this level, if a soup insert is placed into the soup warmer that 

has water filled to this mark without an insert in place, when inserted the 

insert will displace some of the water up the sides of the soup warmer. 

Because the water will level out in the entire system, this may cause the 

reservoir tank of the auto-fill unit to overflow.

S

afety

 p

recaUtionS

To ensure safe operation, read the following statements and 

understand their meaning. Please read carefully.

  

WARNING

Warning is used to indicate the presence of a hazard that 

can

 cause 

severe

 personal injury, death, or substantial property damage if the 

warning is ignored. 

  

CAUTION

Caution is used to indicate the presence of a hazard that 

will

 or 

can

 

cause 

minor

 personal injury or property damage if the caution is 

ignored.

NOTE

Note is used to notify people of installation, operation, or 

maintenance information that is important but not hazard-related.

For Your Safety!

These precautions should be followed at all times. Failure to follow 

these precautions could result in injury to yourself and others.

To reduce risk of injury or damage to the equipment:

 

„

Read and understand all installation and operation instructions before 

installing or operating equipment.

 

„

Have this equipment installed by qualified service personnel.

 

„

Use only grounded electrical outlets matching the nameplate rated 

voltage.

 

„

Do not spray controls or outside of equipment with liquids or cleaning 

agents.

 

„

The control box must be installed in a dry location.

 

„

Do not use an extension cord with this equipment. Do not plug this 

equipment into a power strip or multi-outlet power cord.

 

„

Do not operate without water.

 

„

Keep equipment and power cord away from open flames, electric 

burners or excessive heat.

 

„

Do not operate unattended.

 

„

Do not operate if equipment has been damaged or is malfunctioning in 

any way.

f

Unction

 

and

 p

UrpoSe

This product is intended to maintain the water level in a hot food unit at a 

predetermined level.
This equipment is not intended for household, industrial or laboratory use.

o

perational

 S

tatement

This Auto-fill unit operates by filling a water reservoir that represents an 

additional well. This reservoir has a float switch installed that is closed when 

the tank is empty. When the Auto-Fill system is turned on, the closed float 

switch allows power to flow to the solenoid valve, opening the solenoid valve 

and allowing water to flow into the drain system through a check valve. 
As water fills the drain line, it will fill each well and the Auto-Fill reservoir at 

approximately the same rate. When the water reaches the float switch, the 

switch will open, stopping the power supply to the solenoid valve and the 

solenoid valve will return to its normally closed position stopping the flow of 

water into the system. 

Summary of Contents for 26806

Page 1: ...he equipment read and familiarize yourself with the following operating and safety instructions SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Save the original box and packaging Use this packaging to s...

Page 2: ...some of the water up the sides of the soup warmer Because the water will level out in the entire system this may cause the reservoir tank of the auto fill unit to overflow Safety Precautions To ensur...

Page 3: ...on Start with the valve in the full open position 4 Turn on the Auto fill system using the switch on the control assembly The red indicator light should come on indicating power is supplied to the un...

Page 4: ...DOWN Service and Repair There are no user serviceable parts within this appliance To avoid serious injury or damage never attempt to repair the equipment or replace a damaged power cord yourself Do n...

Page 5: ...BLACK 22860 PILOT LIGHT AMBER 120V 23255 SWITCH TOGGLE F SERIES 17925 WIRE NUT BLACK 22860 CONNECTOR RING 10 STUD 12 10 26559 CORD SET 120V 5 15 PLUG 26550 CONNECTOR RING 10 STUD 12 10 26559 WIRE 1 16...

Page 6: ...4084 Autofill Water Reservoir Subassembly 2 26681 7 16 3 4 Hose Clamp 3 26682 3 8 I D Hose 4 23244 Float Switch 5 23033 Solenoid 6 17925 Switch 120V 7 23255 Pilot Light Amber 120V 8 44082 Autofill Sol...

Page 7: ...OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE As The Vollrath Company LLC s only responsibility and the purchaser s only remedy for any breach of wa...

Page 8: ...NDER THIS WARRANTY YOU MUST REGISTER YOUR WARRANTY Register Today ONLINE Register your warranty on line now at www Vollrathco com NO WEB ACCESS If you do not have access to the web kindly register by...

Reviews: