DIP Switch Settings
DIP Switches allow for the user to manually turn ON/OFF
any port, the external Alarm, or the redundant power
supply. The figure below shows the DIP switch control.
9
Recommended Procedure for configuring and setting
DIP switches during initial installation:
1. Turn all DIP switches OFF.
2. Install the INS-806 into your network.
3. Decide which port(s) need to be monitored or
triggered alarm(s).
4. Turn the corresponding port DIP switch ON.
5. Start the switch for networking operation.
DIP 1
(PWR) controls the primary power
external alarm input. Default is ON.
DIP 2
(RPS) controls the redundant power
external alarm input. Default is ON.
DIP 3-12
represents the alarm for port
numbers of the INS-803 Switch respectively.
Move the DIP switch to the ON position to
manually enable the alarm function. Default is
OFF.