-1-
-2-
-3-
Quick Installation Guide
1. Overview
2. Package Checklist
3. Hardware Installation Procedure
STEP 1:
Take out the device from its packing
STEP 2:
Attach the DIN rail kit as shown in picture
IMC-563P is an Unmanaged PoE+ Industrial Mini-Media
Converter designed for reliable network connectivity
even in tough environment. The converter supports
one 100/1000Base-T RJ45 port with IEEE802.3af/at PoE
standard and one 100FX/1000Base-X SFP slot. With
IP30 protection it exhibits extreme tolerance in harsh
temperature environment ranging from -40°C to 75°C.
IMC-563P quickly installation with no software or
additional configuration needed, proves to be a
perfect solution for round the clock surveillance in
hard-to-reach locations.
IMC-563P is shipped with the following items*. If any of
these are missing or damaged, please contact your
customer service representative for assistance.
IMC-563P Device
DIN rail kit
Quick Installation Guide
* Contents of the package can be adjusted based on
customer demand.
STEP 3:
Connect 48VDC adapter to power input or 48~57VDC
input to terminal block of the IMC-563P
. Please note the "+" & "-" symbols before connecting
terminal block.
STEP 4:
Connect the Ethernet (RJ45) port to the media converter.
See the L/A (Link/Activity) LED to confirm if the connection
is established
IMC-563P
DIN-Rail-mounted with IMC-563P
5. Cabling RJ45
The RJ45 port on the IMC-563P supports auto negotiation
and auto MDI/MDI-X. This feature eliminates the worry
of using specific cable types.
Note: Category 5e cable or above should be used.
The related PoE pinout of
RJ45 is shown in below.
Pin
1
2
3
6
Power
V+
V+
V-
V-
8-pin RJ45
1
8
Removing the Switch
Mounting the Switch
Safety first
!
Turn the power off before connecting modules or wires.
The correct power supply voltage is listed on the
product label. Check the voltage of your power source
to make sure that you are using the correct voltage. Do
NOT use a voltage greater than what is specified on the
product label.
Calculate the maximum possible current in each
power wire and common wire. Observe all electrical
codes dictating the maximum current allowable for
each wire size. If current go above the maximum
ratings, the wiring could overheat, causing serious
damage to your equipment.
Note: Please MUST turn off the power before unplug/plug
DC Jack or Terminal block connector
48~57VDC
-
+
STEP 5:
Insert the SFP module and connect the fiber cable to the
fiber port
4. Location
The IMC-563P can be DIN-Rail-mounted in the cabinet or
enclosure.
PoE
PWR
L/A
100
48~57VDC
48~57VDC
100/1000
100/1000
1000
Panel view
-
+