VOLKTEK HNS-8415P Quick Installation Manual Download Page 2

-4-

-5-

-6-

v1.0

6400-000138

PWR 

RPS

7. LED Indicators

ON: Master power alarm reporting is enabled
OFF: Master power alarm reporting is disabled
ON: Redundant power alarm reporting is enabled
OFF: Redundant power alarm reporting is disabled

PWR

(Green)

 

Illuminated

Terminal block PWR / DC-Jack 

power is connected

Terminal block RPS is

connected

Off

Terminal block PWR / DC-Jack

power fails or is not available

10/100/

1000

Mbps

(Green)

 

Illuminated Copper ports speed at 1000Mbps

Off

Copper ports speed at 

10/100Mbps

PoE

1

st

~4

th

 port

(Green)

 

Illuminated PoE device is connected 

No PoE power output or no 

PoE connected PoE devices

LNK/

ACT

(Green)

 

Illuminated Copper port link-up
Blinking

Data is transmitting / receiving

Off

Off

Port disconnected or link failed

Port disconnected or link failed

Data is transmitting / receiving

SFP

(Green)

 

Illuminated SFP port link-up at 1000Mbps

Blinking

Off

RPS

(Green)

Illuminated

Off

or is not available

Terminal block RPS fails

PWR/RPS fails or is not available

ALM

(Red)

Illuminated
Off

No alarm to report

You can use either “DC-Jack” or  “Terminal Block (PWR)” 

for primary power and “Terminal Block (RPS)” for secondary 

power source, to be a Redundant Power Input. Top views 

of DC-Jack and Terminal Block are shown as picture.

Redundant Power Input

: Choose either “DC-Jack” 

or “Terminal Block (PWR)” as primary power. If you 

choose “Terminal Block (PWR)”, please refer to 

option 1, unless follow option 2.

Insert the “DC-Jack” connector into “DC-Jack” 

receiver and “Terminal Block (RPS)” into terminal 

block receptor.

6.1. Wiring the Redundant Power Inputs

Option 2:

Insert the terminal block connector which includes 

“PWR” and “RPS” into the terminal block receptor.

DC-Jack

Terminal Block

Option 1:

Notice

: Connect power cables to terminal block

Use your finger to press the orange plug on top of 

terminal block connector to insert power cables.

LIMITED WARRANTY

                      Turn the power off before connecting modules 

or wires. The correct power supply voltage is listed on 

the product label. Check the voltage of your power 

source to make sure that you are using the correct

voltage. Do NOT use a voltage greater than what is 

specified on the product label.

Calculate the maximum possible current in each 

power wire and common wire. Observe all electrical 

codes dictating the maximum current allowable for 

each wire size. If current go above the maximum 

ratings, the wiring could overheat, causing serious 

damage to your equipment.

6.2. DIP Switch Setting

PWR
RPS

!

ATTENTION:  

Please use a power supply from 48~57VDC, the device 

power shall be supplied by SELV circuit.

!

ATTENTION

We strongly request that each Industrial PoE switch to 

connect to individual power supply. Please don’t use one 

power supply to two or more PoE switches at a time.

48~57VDC

VOLKTEK Corporation warrants this product against 
defect in materials and workmanship for a period of 
THREE (3) YEARS to the original purchaser.
If you discover a defect, VOLKTEK will, at its sole option, 
repair or replace the product at no additional charge, 
provided that you contact VOLKTEK technical support to 
obtain a Return Merchandise Authorization Number 
(RMA) and instruction on how and where repairs can be 
made. This warranty does not apply if the product has 
been damaged by accident, abuse, misuse, misapplication, 
neglect, fire, water, lightning or other acts of nature, 
failure to follow supplied instructions, installation or 
removal, have been repaired or have undergone 
attempted repair by unauthorized personnel without 
written consent from VOLKTEK, modified, defaced, or has 
its serial numbers removed. VOLKTEK reserves the right 
to use remanufactured, refurbished, or used parts and 
components in making warranty repairs.
All expressed or implied warranties for this product, 
including the implied warranties of merchantability and 
fitness for a particular purpose are limited in duration to 
the warranty period. No warranties expressed or implied 
will applied after this period. VOLKTEK shall not be liable 
for lost profits, damage to other property caused by any 
defects of this product, or damages based upon 
inconvenience, loss of product use, loss of time, 
commercial use, incidental and/or consequential damages 
for the breach of any expressed or implied warranty, 
including damages to property, and to the extent permitted 
by law, damages for personal injury, even if VOLKTEK has 
been advised of the responsibilities of such damages.
If you have any further questions, please contact Customer 
Support:

Address of the manufacturer.

VOLKTEK CORPORATION
4F, 192 Liancheng Rd, Zhonghe, New Taipei 23553, Taiwan 
Email: [email protected]
Tel: +886-2-8242-1000
Fax: +886-2-8242-3333