Operating manual VAS 5051B A01.4 08/04 All rights reserved.
2-11
VAS 5051B
Measurement range kV
Range y
deflection Tolerance
±8 kV
1 kV/DIV
±15 % of m. ±200 V
±20 kV
2.5 kV/DIV ±15 % of m. ±400 V
±40 kV
5 kV/DIV
±15 % of m. ±800 V
The size of the measurement error depends on the
ignition cable insulation and applies to use in vehicle
systems with mechanical distributors. The kV input and
the kV pick-up (ignition voltage adapter) form a capaci-
tive voltage divider. The tester can be adapted to a sta-
tionary ignition distributor system by external
connection of the ignition voltage adapter.
Trigger pick-up input
To record ignition timing on high-voltage cables
(secondary ignition coil)
Trigger functions
Trigger channel
DSO1, DSO2,
Trigger pick-up or
kV pick-up
Trigger coupling
AC, DC, HF, LF
Trigger edge
positive, negative
Trigger level
Automatic or
adjustable in 1 % measu-
rement range increments
Trigger delay
Pre-trigger and post-
trigger, adjustable in
10 % deflection increments
Trigger mode
Single, Normal,
Auto, Auto Level,
Auto Setup,
Draw mode