background image

Vehicle Diagnostic, Testing and Information System
VAS 5051B

Ausgabestand: 06.08.04

Operating manual A01.4

08/04

IBR

 219

Summary of Contents for VAS 5051B

Page 1: ...Vehicle Diagnostic Testing and Information System VAS 5051B Ausgabestand 06 08 04 Operating manual A01 4 08 04 IBR 219...

Page 2: ...and or the tester could result e g Ensure that the touchscreen is not touched with sharp edged objects A Note symbol contains other special instructions for using the device and related information Wa...

Page 3: ...or counter or come in contact with hot manifolds or moving fan blades 4 Warning An extension cord is not allowed For testing use only specified cables 5 Warning Always unplug equipment from electrical...

Page 4: ...with an earthed protective conductor TN networks or electrical out lets with earthed protective conductors 10 Warning All measurement probes shall be used within their specifications and as described...

Page 5: ...type and same amperage may be installed in order to avoid risks of fire and to protect the device To order original parts refer to the corresponding chapters of the Operating Manual 16 Caution when c...

Page 6: ...s cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of th...

Page 7: ...ransmitter must not be co located or operating in conjunction with any other antenna or transmitter Note A Bluetooth interface application for communication with external devices e g diag nostic head...

Page 8: ...non condensing Electrical protection and safety Safety regulations Workshop devices UL 201 Devices for information processing DIN EN 60950 VDE 0805 EN 60950 IEC 950 UL 1950 CSA C22 2 No 950 Testing de...

Page 9: ...er is buffered with the battery Li ION 14 8 V Usually 1 h depending on operating mode battery state and the external consumers Approx 2 5 h only with adapter unit connected Power supply from the vehic...

Page 10: ...tion Smartcard as per ISO 7816 For PCMCIA cards 1 x type III or 2 x type II 2 pin mini SNAP socket size 2 Mini SNAP sockets Diagnosis interface 18 pin Multimeter 14 pin size 3 Storage oscilloscope 12...

Page 11: ...9941 6 8 04 VAS 5051B Mains cable internal Plug type The mains cable approx 3 m is connected to the mains network in the workshop trolley Plug for non heating apparatus type C13 EN60320 C13 Variant 1...

Page 12: ...solution Tolerance 0 to 2 V 0 001 V 1 5 of m 4 mV 0 to 20 V 0 01 V 1 5 of m 40 mV 0 to 40 V 0 01 V 1 5 of m 80 mV Alternating voltage at U R D I effective value 5 kHz to 10 kHz crest factor max 3 Ri 1...

Page 13: ...a diode sym bol During the measurement the polarity of the measu rement current is reversed Direct current via current pick up 100 A Range Resolution Tolerance 5 to 5 A 1 mA 2 of m 10 mA1 50 to 50 A 1...

Page 14: ...001 V 1 of m 8 mV 16 to 16 V 0 01 V 1 of m 20 mV 40 to 40 V 0 01 V 1 of m 40 mV 160 to 160 V 0 1 V 1 of m 200 mV 400 to 400 V 0 1 V 1 of m 400 mV Alternating voltage at DSO1 effective value 30 Hz to 5...

Page 15: ...The measuring input is designed for connection of a pressure sensor with a 4 mA to 20 mA interface Caution Maximum voltage on DSO measuring lead 400 Vpeak or 400 V DC Measuring leads DSO1 DSO2 measuri...

Page 16: ...d 2 9 A5E00309941 6 8 04 VAS 5051B Measurement ranges DSO1 DSO2 Differential inputs Voltage divider 4 M 25 pF against protective conductor potential Range y deflection 0 4 V 50 mV DIV 1 6 V 200 mV DIV...

Page 17: ...p inputs current pick up 100 A 1800 A Pressure or temperature sensor Time base Sampling rate 1 25 s DIV 40 MHz3 2 5 s DIV 20 MHz 5 s DIV 10 MHz 10 s DIV 5 MHz 20 s DIV 2 5 MHz 50 s DIV 1 MHz 100 s DIV...

Page 18: ...n voltage adapter form a capaci tive voltage divider The tester can be adapted to a sta tionary ignition distributor system by external connection of the ignition voltage adapter Trigger pick up input...

Page 19: ...m for testing old vehicles 3 m Cable bend diameter 10 x cable diameter Plug cycles 1 000 Mains cable The mains cable 6 m can be replaced with a mains cable of the type applicable in the country of use...