Channel 

Function 

Time and Value 

DMX 

HEX 

 

 

90° 

 

02..03 

02..03 

1,0 

 

 

180° 

 

04..05 

04..05 

1,7 

 

 

270° 

 

06..07 

06..07 

2,5 

 

PAN 

0° 

 

08..09 

08..09 

3,3 

 

 

90° 

 

10..11 

0A..0B 

4,1 

 

 

180° 

 

12..13 

0C..0D 

4,9 

 

 

270° 

 

14..15 

0E..0F 

5,7 

 

PAN 

0° 

 

16..17 

11..11 

6,5 

 

 

90° 

 

18..19 

12..13 

7,3 

 

 

180° 

 

20..21 

14..15 

8,0 

 

 

270° 

 

22..23 

16..17 

8,8 

 

PAN 

0° 

 

24..25 

18..19 

9,6 

 

 

90° 

 

26..27 

1A..1B 

10,4 

 

 

180° 

 

28..29 

1C..1D 

11,2 

 

 

270° 

 

30..31 

1E..1F 

12 

 

TILT 

size / phase see also PAN 

32..63 

20..3F 

13..25 

 

PAN / TILT 

size / phase see also PAN 

64..95 

40..5F 

26..37 

 

PAN / TILT (inverse) 

size / phase see also PAN 

96..127 

60..7F 

38..50 

 

Circle 

size / phase see also PAN 

128..159 

80..9F 

51..62 

 

Circle (inverse) 

size / phase see also PAN 

160..191  A0..BF 

63..75 

 

Lying eight 

size / phase see also PAN 

192..223  C0..DF 

76..87 

 

Random movement 

size see also PAN 

224..255  E0..FF 

88..100 

14) Speed 

This channel is only for the SPEED of the movements not for 

Pan/Tilt  

0..255 

00..FF 

0..100 

Pan/Tilt 
 

15) Zoom 

Zoom 0% - 100%  

10° - 26° 

0..255 

0..FF 

0..100 

 

1)

 The predefined colors can be used as start colors for the Rainbow effect.  First select a desired start 

color, then activate the rainbow effect. All 

V

V

O

O

L

L

K

K

S

S

L

L

I

I

C

C

H

H

T

T

 

 

Z

Z

O

O

O

O

M

M

 will then begin from that color and 

execute the rainbow effect synchronously. Different 

V

V

O

O

L

L

K

K

S

S

L

L

I

I

C

C

H

H

T

T

 

 

Z

Z

O

O

O

O

M

M

 

 

can have different start 

colors but  will still execute  the rainbow  effect synchronously.  If  you choose a color different from the 

ones marked with 

1)

 in the tables above the rainbow start-color will be red.  

 

2)

 Rainbow-effect Stop will pause this function. After resuming the rainbow-effect will be continued with 

the current color.  

 

3)

 The Rainbow-effect will run synchronously only if it is started from one of the predefined colors (see 

also 

1)

 before). 

 

4)

  Attention:  Please  note  that  shutter  frequencies  over  10  Hz  are  prohibited  in  some  countries. 

Especially frequencies in the range  of 5 - 12  Hz can  possibly cause epileptic seizures 

 continuous 

blink irritation with a latency period of min. 70 ms. Please also refer to the relevant legislation of each 

country  (For  Germany  for  example:  BGI  810-4  (Anhang  2)  "Sicherheit  bei  Produktionen  und 

Veranstaltungen - Scheinwerfer"). 

5)

  The  continuous  color  temperature  correction  applies  only  to  white  i.e.  if  this  function  is  activated 

(DMX 

  001)  the 

V

V

O

O

L

L

K

K

S

S

L

L

I

I

C

C

H

H

T

T

 

 

Z

Z

o

o

o

o

m

m  changes  to  white  and  can  than  be  controlled  in  a  range  of 

3200K - 7200K. A color temperature correction for other colors is therefore not foreseen.  

Summary of Contents for R-G-B / Zoom

Page 1: ...Instruction Manual from software version 1 06 Instruction version 1 6 e mail service glp de Internet http www glp de R G B Zoom...

Page 2: ...R R R G G G B B B Z Z Zo o oo o om m m GLP German Light Products GmbH Instruction version 1 6 from software version 1 06 2 Notes...

Page 3: ...floor upright 7 2 1 2 Mounting in hanging position Head down 7 2 1 3 Mounting in sideway position 7 2 2 Securing the Device 8 2 3 Connections 8 2 3 1 Power Supply 8 2 3 2 DMX 8 3 The Menu Field 9 4 D...

Page 4: ...iption of Device 1 Moving head actively and passively cooled 2 Arm with various cooling vents 3 LCD Display Menu data entry 4 Base with various connectors and Camlock mounting system 5 Carrying handle...

Page 5: ...ture can rotate unhindered through its full range of movement 3 A safety distance of at least 0 5 m to any easily flammable material e g decoration material must be adhered to 4 Attention Don t touch...

Page 6: ...ay and cover on one side arm and the front bezel Pressure in these areas could result in damages which will not be covered by the standard warranty 10 Repair maintenance and installation work should o...

Page 7: ...T T is equipped with four robust rubber feet This allows a firm and safe stand on even surfaces 2 1 2 Mounting in hanging position Head down To operate the V VO OL LK KS SL LI IC CH HT T in an hanging...

Page 8: ...by threading it through one of the two holes provided on the base of the fixture Ensure that the safety wire is securely fastened through the fixture and the fixtures mounting support Install a safety...

Page 9: ...se the Back key to cancel the entry and to go back to the main menu Back Down UP Enter DMX Start Address Reset Special VOLKSLICHT Men BACK ENTER Level1 Level 2 Level 3 Level 4 Remark DMX Start Address...

Page 10: ...Red Input for red adjustments Green Input for blue adjustments DOWN UP Blue Input for green adjustments DMX Monitor Indicates the presently received DMX signal per DMX channel Pan Instantaneous value...

Page 11: ...12 119 70 77 44 46 5 White CTB Color temperature 7200K 120 127 78 7F 47 49 5 Rainbow Effect Stop 2 128 80 50 Rainbow Effect 3 slow fast 129 223 81 DF 51 88 Rainbow Effect random colors slow fast 224 2...

Page 12: ...e rainbow effect All V VO OL LK KS SL LI IC CH HT T Z ZO OO OM M will then begin from that color and execute the rainbow effect synchronously Different V VO OL LK KS SL LI IC CH HT T Z ZO OO OM M can...

Page 13: ...ly throughout its entire life A soft lint free cloth moistened with any good glass cleaning fluid is recom mended Under no circumstances should alcohol or solvents be used to clean the fixture or its...

Page 14: ...LEDs green and 18x LEDs red Wavelength optimized for maximum presentable color space Optical System High efficient Collimator cluster Fix optical carrier with light distribution angle from 10 26 Scat...

Page 15: ...R R R G G G B B B Z Z Zo o oo o om m m GLP German Light Products GmbH Instruction version 1 6 from software version 1 06 15 7 System dimensions in mm 356 290 268 285 80 242 132 12 40 74...

Page 16: ...y 9 I Instruction Version 1 Internet 1 L LED Class 2M 5 M Maintenance 13 Menu Field 9 Micro fuse 8 Mode key 9 Mounting 6 Mounting in hanging Position 7 Mounting in sidewise Position 7 Mounting on the...

Page 17: ...R R R G G G B B B Z Z Zo o oo o om m m GLP German Light Products GmbH Instruction version 1 6 from software version 1 06 17...

Reviews: