background image

4

THINGS YOU SHOULD KNOW

1.1

GAS APPLIANCE
Gas Safety (Installations and Use) Regulations.

In the interests of your safety and that of others it
is a legal requirement that all gas appliances are
installed and correctly maintained by a competent
person and in accordance with the latest regula-
tions.

1.2

ELECTRICAL SUPPLY

Please ensure that this appliance has been prop-
erly connected to the electrical supply by means
of a double pole isolator or un-switched socket,
and that the correct size of fuse (3 AMP) has been
fitted.

Warning: this appliance must be earthed!

1.3

GUARANTEE REGISTRATION CARD

Please take the time to fill out your guarantee
registration card. The completed warranty card
should be posted within 30 days of installation.

1.4

BENCHMARK LOG BOOK

A benchmark checklist is included within the
installation booklet. This important document must
be completed during the installation/commission-
ing of your boiler. Failure to install and commission
the appliance in accordance with the manufactur-
ers instructions may invalidate the warranty. This
does not affect your statutory rights.

1.5

HOW DOES IT WORK?

Your Mynute HE boiler is a high efficiency central
heating boiler, which supplies heated water to your
radiators and hot water cylinder. The central heat-
ing and hot water is controlled via a programmer
and any thermostats that your installer may have
fitted. The boiler lights electronically and does not
have a pilot light. In the unlikely event of a fault
developing with your boiler, the supply of gas to
the burner will be terminated automatically.

1.6

DIMENSIONS

HEIGHT

WIDTH

DEPTH

845 mm
453 mm
359 mm

1.7

CLEARANCES REQUIRED

ABOVE

BELOW

SIDES

FRONT

150 mm
150 mm

12  mm

600 mm

1.8

FROST PROTECTION SYSTEM

The Mynute HE is equipped with a built-in frost
protection system, this enables the boiler to over-
ride the time controls - if switched off - and operate
the burner and/or pump, should the temperature
drop below 7°C.
Please note that the frost protection system is
designed to protect the appliance only, should
frost protection be required for the central heating
system, additional controls may be required.

NOTE

The frost protection system is reliant on the ap-
pliance having a permanent electrical supply, and
being in a non-fault condition.

Summary of Contents for MYNUTHE 35 HE

Page 1: ...Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER G C NUMBER MYNUTE 35 HE N 410 94 44 0694 0694BQ0479...

Page 2: ...ually Contents Introduction Page Dear customer 2 Do s and don t s 2 Things you should know Page 1 1 Gas appliances 4 1 2 Electrical supply 4 1 3 Guarantee registration card 4 1 4 Benchmark log book 4...

Page 3: ...utton 3 MODE button 4 INFO button Currentwaterpressure Outside sensor Currentappliancetemperature Errorcode Currentmodeofoperation Burneron Frost protection on Symbolsdescription Economy Comfort Heati...

Page 4: ...ate the warranty This does not affect your statutory rights 1 5 HOW DOES ITWORK Your Mynute HE boiler is a high efficiency central heatingboiler whichsuppliesheatedwatertoyour radiatorsandhotwatercyli...

Page 5: ...ol througha limited temperature range of 55 65 C Winter During the comfort mode the SARA booster function is active Automatic Temperature Con trol throughtheentiretemperaturerangeof30 80 C 2 3 2 FUNCT...

Page 6: ...ait 13 14 Wiring fault Call engineer 20 21 22 Heat exchanger temperature too high Call engineer 23 31 Wiring fault Wait 30 Wiring fault Call engineer 32 34 Fan fault Call engineer 33 35 Fan fault Wait...

Page 7: ...rtain information on the working status of the boiler Push the Info button to enter the info menu fig 2 Thefollowinginformationareshown pushing subsequently the button Info 1 N A Info 2 water pressure...

Page 8: ...sure gauge is indi cating the correct level Allow a period of two minutes to elapse before pressing the reset but ton IMPORTANT If the appliance requires to be reset frequently it may be indicative of...

Page 9: ...SYSTEM Ifthesystemregularlyrequirestopping up itmay be indicative of a leak Please contact your in staller and ask him to inspect the system 4 3 WHAT IF THE RESET LIGHT IS ON f the reset light is on i...

Page 10: ...10 NOTE...

Page 11: ...11...

Page 12: ...870 333 0520 Fax 01442 281403 After Sales Service Tel 0870 333 0220 Vok ra Ireland West Court Callan Co Kilkenny Tel 05677 55057 Fax 05677 55060 Vok ra Ltd reserve the right to change the specificatio...

Reviews: