Supplied By www.heating spares.co Tel. 0161 620 6677
30
PCB
display PCB
display PCB
display PCB
INTERNAL COMPONENT
Gas valve
Fan
Condense pressure switch
Flow sensor
Return sensor
Pump
External transformer
24V connection for time clock or
room thermostat
Status LED
SYMBOL
OPE
F
P.S.
S1
S2
P
R.T.
L1 L2
DESIGNATION
Plug X2 on main PCB
Plug X2 on main PCB
Plug X2 on main PCB
Plug X3 on main PCB
Plug X3 on main PCB
Plug X1 on main PCB
Plug X10 on main PCB
Appliance terminal strip (terminals& )
Plug X20 on display PCB
PLUG or CONNECTION
X7A
X9
X20
DESIGNATION
Connection from main PCB
Unused
Status LED connection
LOCATION
Appliance terminal strip
Appliance terminal strip
Appliance terminal strip
Appliance terminal strip
Appliance terminal strip
Appliance terminal strip
Appliance terminal strip
Appliance terminal strip
Appliance terminal strip
TERMINAL
1
2
3
4
5
6
7
8
9
DESIGNATION
Earth connection
Live connection
Neutral connection
24V connection
Spare
24V connection
Spare
Spare
Spare
PCB
Main PCB
Main PCB
Main PCB
Main PCB
Main PCB
Main PCB
Main PCB
Main PCB
Main PCB
PLUG or CONNECTION
X1
X2
X3
X7
X8
X10
F1
F2
F3
DESIGNATION
Incoming 230V supply & pump connection
Fan connection, condense pressure switch
connection, gas valve connection
Sensor connections
Display board connection
Unused
External transformer connection
2AF fuse
2AF fuse
4AT fuse