12
Compact
4.5.3.2 INSTALLATION OF CONDENSATE DRAIN KIT
(fig. 10B)
The condensate drain kit must be fitted within 1 metre
of the appliance flue outlet. It is recommended that
the condensate drain kit should be fitted in the vertical
plane, however it can be fitted horizontally with care.
●
Fit the first bend to the condensate drain kit or
exhaust connection manifold by firmly pushing
in to position.
●
Using the two holes in the exhaust connection
manifold as a guide, drill a 3 mm hole in each
and secure using the screws provided.
●
Connect the air inlet pipe to the air baffle as above.
●
The twin flue pipes extensions and accessories
can now be installed by pushing together (the
plain end of each extension or bend should be
pushed approximately 50 mm into the female
socket of the previous piece).
The condensate drain trap must be connected
to the drain in accordance with building
Regulations or other rules in force.
Compact
28
Total flue length
Restrictor required
Less than 4 + 4
Less than 8 + 8
Less than 12.5 + 12.5
Less than 14 + 14
45 mm diameter
47 mm diameter
49 mm diameter
Not required
The Vokera twin flue system enables greater flue
distances to be achieved (see section 2.8) than
that of the standard concentric flue system. It can
be used for horizontal or vertical applications,
however the twin flue system must be converted
to the dedicated concentric flue kit for termination.
It is essential that the installation of the twin flue
system be carried out in strict accordance with
these instructions.
GUIDANCE NOTES ON TWIN FLUE
INSTALLATION
●
The flue must have a fall back of 1º back to the
appliance to allow any condensate that forms
in the flue system to drain. Consideration must
also be given to the fact that there is the
possibility of a small amount of condensate
dripping from the terminal.
●
Ensure that the entire flue system is adequately
supported, use at least one bracket for each
extension.
●
Extreme care must be taken to ensure that no
debris is allowed to enter the flue system at
any time.
●
As the exhaust outlet pipe can reach very high
temperatures it must be protected to prevent
persons touching the hot surface.
Twin flue accessories
Part No.
Description
Length
0225805
Horizontal flue terminal
1.0 metre
0225810
Vertical flue terminal
1.0 metre
300
Twin adapter kit for Compact 24
N/A
2359249
Twin adapter kit for Compact 28
N/A
0225770
Pitched roof flashing plate
N/A
0225765
Flat roof flashing plate
N/A
0225815
Condensate drain kit
N/A
0225820
0.25 m extension (pair)
250 mm
0225825
0.5 m extension (pair)
500 mm
0225830
1.0 m extension (pair)
1000 mm
0225835
2.0 m extension (pair)
2000 mm
0225840
45º bend (pair)
N/A
0225845
90º bend (pair)
N/A
0225850
Twin bracket (5)
N/A
0225855
Single bracket (5)
N/A
MOUNTING THE BOILER
The fixing holes for the wall-mounting bracket
should now be drilled and plugged, an
appropriate type and quantity of fixing should be
used to ensure that the bracket is mounted
securely. Once the bracket has been secured to
the wall, mount the appliance onto the bracket.
4.5.3.1 INSTALLATION OF TWIN ADAPTOR KIT (fig. 10 &
10A)
●
Insert the exhaust connection manifold (B) onto
the appliance flue outlet and secure to the flue
spigot using the screws provided.
●
Insert the silicone seal into the exhaust outlet.
●
Remove the blanking plates (located to the left
of the appliance flue outlet) and – using the
same screws – install the air baffle (A).
Fig. 10
Fig. 10A
Condensate drain kit
restrictor ring
restrictor ring
flue outlet
flue outlet
air inlet
air inlet
Compact
24
Compact
28
Fig. 10B