Vokera Compact 29kW Quick Help Guide
Move 2 Green Ltd, Units 7&8, Sands Industrial Estate, Swalwell, Newcastle upon Tyne, NE16 3DJ
Tel 0191 496 1888 Fax: 0191 488 8812 [email protected] www.move2green.org.uk
Page 1 of 3
Rev 00 -‐ 08/13
BOILER STATUS LED
Green LED
Boiler is working/responding to a heating/hot water request
Red LED
Boiler has identified a fault and has failed-safe. Refer to instructions on how to reset
Yellow LED
Service operation (Boiler requires a service)
HOT WATER TEMPERATURE SELECTOR
Move the selector clockwise to increase the hot water outlet temperature, or counter-clockwise to reduce the temperature
PRESSURE GAUGE
Ensure the system pressure is set correctly (minimum 0.5-bar) - (Normal pressure 1.0 - 1.5 bar)
MODE SELECTOR SWITCH/HEATING TEMPERATURE SELECTOR
Mode selector switch:
3OHDVHQRWHWKHVZLWFKZLOOW\SLFDOO\EHTXLWHVWLIIZKHQWXUQLQJIURPWKHR·FORFNWRWKH%RLOHURIIRUWRWKHR·FORFNSRWZDWHURQO\
MODE
SELECTOR
SWITC
+
RED LED
GREEN LED
+(
ATING
TEMPERATURE
SELECTOR
PRESSURE GAUGE
(Correct Pressure 1.0 - 1.5 Bar)
BOILER
STATUS LED
+27:$7(5
ONLY MODE
BOILER OFF
POSITION
+27:$7(5
TEMPERATURE
SELECTOR
RADIATOR
TEMPERATURE
SELECTOR
YELLOW LED
92.(5$&203$&7.:0$,1&21752/6
Hot water only
- Select this position if you want the boiler
to supply hot water only (no heating)
Hot water temperature selector
: move the selector
clockwise to increase the heating outlet temperature, or
counter-clockwise to reduce the temperature (range:
&&
)
Boiler at OFF/standby
- Select this position when you
want the boiler to be switched off for short periods (days)
or if the boiler requires to be reset.
E.g. Set the boiler to this position when on holiday.
Please do not switch the boiler off at the mains
;
the boiler has an anti-block function which enables the
pump anddiverter valve actuator to be energised for short
periods when the appliance has been inactive for more than
24-hours.
Heating & hot water
- Select this position when you
want the boiler to respond to a heating and hot water
request from the time-clock programmer
Heating temperature selector
: move the selector
clockwise to increase the heating outlet temperature, or
counter-clockwise to reduce the temperature (range:
&&
for standard central heating).
Pressure gauge
shows the current pressure of your
heating system, the gauge should be set between 1 and
SEE Boiler Pressure Setting Instructions Page 3
1.5 BAR. When the appliance is operating the gauge may
rise or fall slightly, this is quite normal. The minimum
permissible level for the safe and efficient operation of the
appliance is 0.5 BAR. Should the pressure fall below 0.5
BAR, the boiler may lockout.