Vokera Compact 29kW Quick Help Guide 

 

Move   2   Green   Ltd,   Units   7&8,   Sands   Industrial   Estate,   Swalwell,   Newcastle   upon   Tyne,   NE16   3DJ   

Tel   0191   496   1888               Fax:   0191   488   8812                  [email protected]                  www.move2green.org.uk   

Page   1   of   3   

Rev   00   -­‐   08/13   

   

BOILER  STATUS  LED

Green LED 

 Boiler is working/responding to a heating/hot water request

Red LED

  Boiler has identified a fault and has failed-safe. Refer to instructions on how to reset

Yellow LED 

 Service operation (Boiler requires a service)

HOT WATER TEMPERATURE  SELECTOR

Move the selector clockwise to increase the hot water outlet temperature, or counter-clockwise to reduce the temperature

PRESSURE  GAUGE

Ensure the system pressure is set correctly (minimum 0.5-bar) - (Normal pressure 1.0 - 1.5 bar)

MODE  SELECTOR  SWITCH/HEATING TEMPERATURE  SELECTOR

Mode selector switch: 

3OHDVHQRWHWKHVZLWFKZLOOW\SLFDOO\EHTXLWHVWLIIZKHQWXUQLQJIURPWKHR·FORFNWRWKH%RLOHURIIRUWRWKHR·FORFNSRWZDWHURQO\

MODE

SELECTOR

SWITC

+

RED LED

GREEN LED

+(

ATING

TEMPERATURE

SELECTOR

PRESSURE GAUGE

(Correct Pressure 1.0 - 1.5 Bar)

BOILER 
STATUS LED

+27:$7(5

ONLY MODE

BOILER OFF
POSITION

+27:$7(5

TEMPERATURE

SELECTOR

RADIATOR

TEMPERATURE

SELECTOR

YELLOW LED

92.(5$&203$&7.:0$,1&21752/6

Hot water only 

- Select this position if you want the boiler

to supply hot water only (no heating)

Hot  water  temperature  selector

:  move  the  selector

clockwise to increase the heating outlet temperature, or
counter-clockwise  to  reduce  the  temperature  (range:

ƒ&ƒ&

)

Boiler at OFF/standby

 - Select this position when you

want the boiler to be switched off for short periods (days)
or if the boiler requires to be reset.

E.g. Set the boiler to this position when on holiday.

Please do not switch the boiler off at the mains

the boiler has an anti-block function which enables the  
pump anddiverter valve actuator to be energised for short 
periods when the appliance has been inactive for more than 
24-hours.

Heating  &  hot  water

  -  Select  this  position  when  you

want  the  boiler  to  respond  to  a  heating  and  hot  water
request from the time-clock programmer

Heating  temperature  selector

:  move  the  selector

clockwise to increase the heating outlet temperature, or
counter-clockwise  to  reduce  the  temperature  (range:

ƒ&ƒ&

 for standard central heating).

Pressure  gauge

  shows  the  current  pressure  of  your

heating system, the gauge should be set between 1 and

SEE Boiler Pressure Setting Instructions Page 3 

1.5 BAR. When the appliance is operating the gauge may
rise  or  fall  slightly,  this  is  quite  normal.  The  minimum
permissible level for the safe and efficient operation of the
appliance is 0.5 BAR. Should the pressure fall below  0.5
BAR, the boiler may lockout.

  correct

pressure

value

Fig 1

Fig 1a

Fig 1b

Fig 1c

Fig 1d

A

A

B

B

C

C

D

D