Void STASYS 3 mk2 Owner'S Manual Download Page 3

Stasys

Page 3

Reference Manual

 Features

Close tolerance and durable components provide increased reliability and greater output.  
2 way - 3 way Active mode switch.
Unique 'waveformer' loading system ensures flat and even dispersion when arraying.  
Accurately machined 15 laminate birch plywood cabinets for superior strength and longevity.

Built in Electronic Protection devices for both HF and MF drivers.

4 Aero Track Flying points for fast and accurate installation.
8 balanced grab handles for easier mobility.

Tough kick proof grills with foam filters protect the components from the heaviest of abuse.
Three year warranty and guarantee.

  System Connections

          In 2 way active mode Stasys 3 use's the 4 pole speakons. Pins +1 and -1 are connected to the LF   

          section and pins +2 and -2 are connected to the MHF section. An internal 3.2 KHz 2 way passive

          crossover is used between the MF and HF sections when Stasys 3 is used in 2 way passive mode.

          The suggested crossover frequency in 2 way active mode is 800 Hz between the LF and the MHF

          sections.

          In 3 way active mode the Stasys 3 use's the 8 pole speakons. Pins +1 and -1 are connected to the LF

          section, pins +2 and -2 are connected to the MF section and pins +3 and -3 are connected to the HF

          section. Pins +4 and -4 are not used. Programs are available for the Digidrive and Livedrive processors

          which set the correct frequencies, filter type and slope for both 2 way and 3 way active modes.  

          The switch to change operating modes can be found on the rear connector panel.

 

          Stasys 3's 4 pole speakon connectors are wired in parallel, the 8 pole speakons are also wired in

          parallel, so either speakon can be used as the input. The other speakon can be used as a link output.

          

                              Do not connect to the 4 pole and 8 pole speakons at the same time 
                      Please make sure the rear panel switch is set for the correct operating mode     

 Precautions

Please consider the following precautions during use :

1. Install the Stasys 3 enclosure in a dry environment, do not expose the cabinet to rain or moisture.

2. When flying or mounting the Stasys 3 ensure safe working practices and follow the recommended  

    rigging guidelines.

3. The Stasys 3 enclosure contains very powerful magnets. Do not locate an enclosure near any

    sensitive equipment such as: VDU monitors, CRT TV's or high gain preamplifiers. 

Reviews: