Void Bias D1 User Manual Download Page 12

voidacoustics.com

N O R T H   A M E R I C A

Void Acoustics North America

Call:

 +1 503 854 7134 

Email:

 [email protected]

H E A D   O F F I C E

Void Acoustics Research Ltd,  
Unit 15, Dawkins Road Industrial Estate,  
Poole, Dorset,  
BH15 4JY  
United Kingdom

Call:

 +44(0) 1202 666006 

Email:

 [email protected]

Void Acoustics Research Limited is a company registered in England and Wales registration number 07533536

Summary of Contents for Bias D1

Page 1: ...voidacoustics com Bias D1 Q1 Q2 Powering the future of sound U SER GUIDE V2 0...

Page 2: ...t notice For the latest online version visit www voidacoustics com Void Acoustics and the Void logo are registered trademarks of Void Acoustics Research Ltd in the United Kingdom USA and other countri...

Page 3: ......

Page 4: ...MENTAL REQUIREMENTS OF SAFETY AND IN CASE OF DOUBT REQUIRE AN ACCURATE CHECK BY QUALIFIED PERSONNEL Common symbols and meanings CLASS3 WIRING THE TRIANGLE WITH THE LIGHTNING BOLT IS USED TO ALERT THE...

Page 5: ...been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules This equipment generates uses and can radiate radio frequency energy and if not insta...

Page 6: ...he amplifier On and Off The Bias amplifiers can operate with different gain applied to the input signal This feature is designed to match the voltage of the input signal A proper combination of the po...

Page 7: ...th very low loads by limiting the maximum output voltage to 85 Vpeak per channel For optimal 2 performance it is recommended to select LowZ mode for all the amplifier s channels Note that 2 capabiliti...

Page 8: ...Page 8 1 1 1 RU 1 RU 1 RU 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 Location Exposing the Control Panel Cooling Dimensions 442 mm 19 0 in 14 0 in 373 mm 14 7 in 357 mm 365 5 mm 14 4 in...

Page 9: ...2 3 4 5 6 7 8 26 dB 29 dB 32 dB 35 dB 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CH1 MASTER BRK SAVE NRG SAVE USR A 2 3 2 3 2 3 2 3 1 4 5 6 7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2...

Page 10: ...3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 2 1 70V lo Z 35Hz HPF Off 100V hi Z 70Hz HPF On 70V lo Z 35Hz HPF Off 100V hi Z 70Hz HPF On 70V lo Z 35Hz HPF Off 100V hi Z 70Hz HPF On 70V lo Z 35Hz HPF Of...

Page 11: ...ult1 1 Red LED lights on in case of any kind of channel fault that prevents the normal channel operating LED Bars signal metering 8 Color Name Operating mode Standby Power On GREEN POWER ON SOLID ON O...

Page 12: ...usa voidacoustics com HEAD OFFICE Void Acoustics Research Ltd Unit 15 Dawkins Road Industrial Estate Poole Dorset BH15 4JY United Kingdom Call 44 0 1202 666006 Email info voidacoustics com Void Acoust...