background image

Exideal Operating Procedures / 10 Care support

  

Program

7

8

Please connect the AC adaptor 

into the device.

1

Press a button on the control 

panel to turn on power

2

Please use Exideal exclusive goggles 

when you use this product.

●Programs that require the goggles

P01, P03, P05, P07, P08, P09, P10

90°

10cm〜30cm

Please select the program you like 

by checking the program number 

with the up-down button from the 

control panel.

3

5

7

8

9

Please wear the goggles if the other 

programs require the goggles.

Adjust for irradiation angle 

and irradiation distance.

4

Start irradiation by pressing the start 

button. Please press the start button 

once again to abort the program.

Operating Procedures

(1) Go off a startup-sound.

(2) Program number on display monito

r.

     (First time sound is P01.

      Last  operation of program number is

      shown after the 2nd time.)

Press SET.SELECT button for 

time setting     when you decide 

to use the program.

(1) Select irradiation program with UP/Down button.

(2) P

 button: One click and show P01 to P10 → P01 in orde

r.

(3) DOWN button: One click and show P01 to P10 → P09 to P01 in order

.

(4) Displayed-Program without select program starts immediately when you press the start

      button.

Please do a patch test before using it for 

  the first time. (

P.4)

Y

ou can use the lotion before, during, and 

  after irradiation.

*Y

ou can use basic skin-care products such

  as  lotion and cream.

Please set the timer (maximum for 30 

mins) with the UP/DOWN button from 

the control panel while checking 

displayed-monitor for irradiation time.

(1) 

The initial display shows for default value program (Standard irradiation time).It can be

     operated by procedure  

7

  if there is no change.

(2) 

The UP/DOWN button can change the irradiation time.

(3) U

P

 Button: One click and show 1 to 30 → 1 in order in every 1 mins.

(4) DOWN Button: One click and show 1 to 30 → 29 to 1 in order in every 1 mins.

(5) 

It memorizes previous action time when you press the start button during set to irradiation time.

(6) 

It changes configuration of previous action of irradiation program time during irradiation time.

(7) 

Program number and selecting time on the display-monitor can be confirmed.

 To do so press the

      set-button with set to program and time in a series of operations without the UP/DOWN button.

(1) 

After you finish setting the irradiation program and timer start the program by using the start 

     button.Pressing the start button will activate the lights 

on the start-display (red-color).

(2) Irradiation starts after the 5 second countdown on the display-monitor when choosing a 

     program that uses goggles. (Please place on the goggles wi

thin the 5 seconds)

(3) Pressing the button starts irradiation for programs that do not require goggles.

(4) It shows on display monitor in 5 seconds during program.

(5) Pressing the SELECT

 button during a program stops irradiation with a pause sound.It confirms

     pause state and changes the start-display to a flashing (red-light).

(6) Pressing the SELECT

 program once again restarts the program.

(7) Pressing the start button during program and pause stops the program in process.It becomes

     possible to reset the program and also resets the countdown time

r.

(8) Pressing the start button memorizes the executed program.It always memorizes the previous

     program and shows it in the next selection program.

Please wear the exclusive 

    goggles when necessary.

6

10 Care Support Programs

Please use it for smooth skin care support.

Stand still for aging skin.Please clean your hands when you clean your skin. Please use our program 

after conditioning your skin with a tone

r

.It is important that you not only take care of your skin, but also 

take care of the inside of your body by living a healthy daily lifestyle (diet and enough sleep).

■Advice and 

Tips

For the program P03, please use the exclusive goggles and close your eyes during irradiation.For the 

program P04, the LED light is not strong, but please close your eyes during irradiation.Program P02 

has a time division control, but it has the same power and e

f

fect as program P03.Caution: Please do 

not use it vigorously when you have inflammation of the skin.

■Using the goggles

Please use for texture firmness skin care support.

It is important to moisturize your skin for texture firmness skin care.It is better to do our treatment 

program after warming your skin with a hot towel and conditioning your skin with a toner

, lotion and 

cream.It treats all age types for texture firmness aging care.

■Advice and 

Tips

For the program P01, please use the exclusive goggles and close your eyes during irradiation.For the 

program P02, the LED light is not strong, but please close your eyes during irradiation.Program 02 has 

a time division control, but it has the same power and e

f

fect as program P01.

■Using the goggles

Control value

Basic irradiation 

time

Control value

Basic irradiation 

time

5

P01 With Goggles

P02 Without Goggles

■Basic irradiation program

Our original skin care support program is e

f

fectively combined with the 4 wavelength LED.Please choose your skin 

type program.

■Caution

Please do not use it if directed by a physician or while taking medication.Our care-support-treatment program is not a 

medical treatment for the skin.

Caution

Please do not use it vigorously when you

have inflammation of the skin.

Also do not use it if directed by a physician 

or while taking medication.

Program 01 & 02: Texture firmness skin care support program

Program 03, 04: Adolescent Skin Care Support Program

No sound during silent mode.

Use Silent Mode

(1) Press POWER button, SE

T, SELECT

 / II button, S

TA

RT / S

T

O

P

 button at same time.

(2) Press STA

RT/S

T

O

P

 button to begin irradiation.

Please do (1) to stop silent mode.

1

2

※Please close your eyes when using

Clean your face with the cleanser 

and spread the special lotion over

your entire face.

6

minutes

12

minutes

Control value

Basic irradiation 

time

Control value

Basic irradiation 

time

5

P03 With Goggles

P04 Without Goggles

※Please close your eyes when using

minutes

10

minutes

Summary of Contents for Exideal EX-280

Page 1: ...arranty is for only in Japan 7 We do not reissue this warranty Purpose for usage of Personal Information and other We will maintain and use customer information copy of warranty in accordance with limited warranty of free repair and safety inspection This warranty is promise of indication of limited warranty for free repair It does not set a limit to the customer s legal rights and obligations for...

Page 2: ...ch moisture or next to water lavatory vanity It could be a fire hazard short circuit or cause insulation deterioration When you stop using the device please turn off the power and pull the power cord from the outlet Smoke from this product Unusual heat Unusual noise Unusual smell etc Warning Pull power code Please do not modify or re assemble without the assistance of a repair engineer It could re...

Page 3: ...ute longer Press the DOWN button to change to another control value and to reduce the irradiation program timer by one minute shorter between 1min and 30min 3 WAKE UP timer can also be used to select hour minute 6 Display Monitor 1 Irradiation program It displays program number on the left P and double digits on the right Ex P 05 2 Timer It displays double digits of timer minute on the right Ex 15...

Page 4: ... T Zone is independently controlled so you can treat your entire body and provide T Zone care at the same time 2 Contactless Beauty Device Maximum 10000 times second pulse output The 280 of 4 wavelength LED for ultra high brightness light is incomparable and designed for wide range irradiation home use The entire base panel is our original optical design with a finished mirror surface of dermis in...

Page 5: ...contents of multiple functions Safety Functions Cautions on Use Program 09 Total care support in the fall and winter Program 10 Total care support in the spring and summer Cautions on Use Safety Functions 1 Please use this device at a unit temperature between 15 C and 40 C Adequate irradiation treatment might not be received if the temperature is not within normal range of use It could require the...

Page 6: ...lay to a flashing red light 6 Pressing the SELECT program once again restarts the program 7 Pressing the start button during program and pause stops the program in process It becomes possible to reset the program and also resets the countdown timer 8 Pressing the start button memorizes the executed program It always memorizes the previous program and shows it in the next selection program Please w...

Page 7: ...tant for skin care A NO It does not directly affect your eyes There are stronger lights in our daily life Some programs emit a momentary brightness that can blind you temporarily please use the goggles required by those programs 1 Please close your eyes even if the other programs do not require the goggles A No problem Please use the goggles required by those programs 1 and also do not look direct...

Page 8: ...ptor is not connected properly into the device Please connect AC adaptor for sure The AC adaptor is not connected properly to the device or there was a power outage Please connect AC adaptor for sure and reset wake up mode for power outage Was there any static discharge by a person during the winter This device has micro computer monitoring functions that detect large static discharges When detect...

Reviews: