background image

Page 2

 

 SHILOH™

 

Vogelzang International Corp.

 

TR002B | 20120125.0

SAFETY INSTRUCTIONS-Read All Instructions Carefully.

1.  The installation of this stove must comply with your 

local building code rulings. Please observe the clear-
ances to combustibles (see reference figures 10–12). 
Do not place fuel, furniture or any other objects within 
the clearance area.

2.  Verify that the stove is properly assembled and 

installed before firing the stove for the first time. 
After reading these instructions, if you have any 
doubt about your ability to complete your installation  
properly, you must obtain the services of a  
professional licensed installer familiar with all  
aspects of safe and correct installation.  DO NOT  
use temporar y or makeshift compromises  
during installation. There must be 

NO DEVIATION 

OR ALTERATION OF ANY KIND from the very spe-
cific instructions spelled out in this instruction manual 
as it pertains to the installation of this woodstove. 

 

NO EXCEPTIONS!

3.  DO NOT store wood, kindling, flammable liquids 

or other combustible materials in the vicinity of the 
appliance. Refer to certification label on back of unit 
and reference figures 10–12 in this manual.

4. 

DO NOT INSTALL THIS STOVE IN A MOBILE 
HOME, MANUFACTURED HOME, TRAILER OR 
TENT NO EXCEPTIONS! (HUD Federal Standard: 
24 CFR Ch.XX).

5. 

DO NOT ELEVATE THIS STOVE BY ANY MEANS. 
(i.e. bricks under pedestal base, cement blocks)  
Stove base must set directly upon the solid-surface, 
non-combustible floor as specified in this stove 
instruction manual. 

6. 

DO NOT MODIFY THIS STOVE IN ANY WAY! Stove 
must be installed with pedestal stand provided and 
attached as shown in the instructions. 

DO NOT OP-

ERATE WITHOUT ASH DRAWER OR ASH CLEAN 
OUT COVER IN PLACE 
– NO EXCEPTIONS. As-
semble only with original parts as supplied and shown 
in this manual. 

DO NOT OPERATE A STOVE THAT 

IS MISSING ANY PARTS! If any parts are missing 
or defective, please notify the dealer or manufacturer 
immediately. Replace missing, broken or worn parts 
with factory original or equivalent parts only.

7. 

CAUTION: DO NOT ALTER COMBUSTION AIR 
CONTROL RANGE TO INCREASE FIRING OR 
FOR ANY REASON. 
Altering or tampering with air 
control beyond normal capacity will create unsafe 
and hazardous conditions.

8.  Always connect this stove to a chimney and vent to 

the outside. Never vent to a room or inside a build-
ing. 

DO NOT CONNECT THIS UNIT TO A CHIMNEY 

FLUE SERVING ANOTHER APPLIANCE.

9. 

DO NOT CONNECT A WOOD BURNING STOVE TO 

AN ALUMINUM TYPE B GAS VENT. This is not safe. 
Use approved masonry or an Underwriters Labo-
ratories Listed UL 103 HT (US)/ULC-S629 (CDN) 
Residential Type and Building Heating Appliance 
Chimney. Use a 6˝/152mm diameter chimney, that 
is high enough to give a good draft. (See specifics 
in Chimney Connections instructions).

10.  Be sure that your chimney is safely constructed and 

in good repair. Have the chimney inspected by the fire 
department or a qualified inspector. Your insurance 
company should be able to recommend a qualified 
inspector. Chimney connector pipe must be in good 
condition. Replace if necessary before using stove.

11.  Creosote or soot may build up in the chimney con-

nector and chimney and cause a house/building 
fire. Inspect the chimney connector and chimney 
twice monthly during the heating season and clean 
if necessary. (see Service Hints). 

12.  In the event of a chimney fire, turn the air controls to 

closed positions, leave the building and 

CALL THE 

FIRE DEPARTMENT IMMEDIATELY!  Have a clearly 
understood plan on how to handle a chimney fire by 
contacting your local fire authority for information 
on proper procedures in the event of a chimney fire.  
After the fire is out, the chimney must be cleaned 
and inspected for any stress or cracks before starting 
another fire. Check the condition of any combustibles 
surrounding the chimney.

13.  Ashes should not be allowed to accumulate above 

the top of the lower primary air orifice (LPAO, air vent 
at front of firebox, just inside of door).

14. 

DISPOSAL OF ASHES  Ashes should be placed 
in a steel container with a tight fitting lid and moved 
outdoors immediately. The closed container of ashes 
should be placed on a noncombustible floor or on the 
ground, well away from all combustible materials, 
pending final disposal. If the ashes are disposed of 
by burial in soil or otherwise locally dispersed, they 
should be retained in the closed container until all 
cinders have completely cooled. Other waste shall 
not be placed in this container.

15.  To prevent injury, do not allow anyone to use this 

stove who is unfamiliar with the correct operation of 
the stove.

16.  Do not operate stove while under the influence of 

drugs or alcohol.

17. 

DO NOT ELEVATE THE FIRE. Build fire directly on 
the bottom of the firebox. This stove has not been 
tested with the use of grates, andirons or other means 
of elevating the fire and must not be used.

18. The special paints used on your stove may give 

off some smoke and an odor while they are cur-

Summary of Contents for TR002B

Page 1: ...c 2 READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS STOVE FAILURE TO FOLLOW INSTRUC TIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH NOTE IT IS RECOMMENDED INSTALLATION BE COMPLETED BY A QUALIFIED HEATING EQUIPMENT INSTALLER DO NOT INSTALL IN A MOBILE HOME REFER TO MARKINGS ON STOVE LABELS FOR ADDITIONAL INFORMATION This stove meets test standards US UL 1482 2010...

Page 2: ...MNEY FLUE SERVING ANOTHER APPLIANCE 9 DO NOT CONNECT AWOOD BURNING STOVETO AN ALUMINUMTYPE B GASVENT This is not safe Use approved masonry or an Underwriters Labo ratories Listed UL 103 HT US ULC S629 CDN Residential Type and Building Heating Appliance Chimney Use a 6 152mm diameter chimney that is high enough to give a good draft See specifics in Chimney Connections instructions 10 Be sure that y...

Page 3: ...uch a manner that it creates a hazard when opening the door 28 NEVER LEAVE THE STOVE UNATTENDED with door open Always close the door after ignition 29 DO NOT CONNECT TO OR USE IN CONJUNC SAFETY INSTRUCTIONS continued TIONWITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS 30 A WOOD BURNING STOVE MUST NEVER BE INSTALLED IN A HALLWAY OR NEAR A STAIR CASE as it may ...

Page 4: ...azards Operating Precautions Warnings 16 Wood Types Sizes 16 Optimal Fuel Consumption 16 Starting a Fire 17 Adding Fuel 17 SERVICE HINTS Creosote Formation Prevention Removal 18 Chimney Draft 19 Glass Care Replacement 20 Glass Gasket Replacement 20 Door Gasket Replacement 21 OPTIONAL F 6 BLOWER MAINTENANCE WIRING DIAGRAM 21 PARTS SHILOH 22 PARTS GLASS DOOR 23 PARTS FIRE BRICK 23 FLOOR PROTECTOR CA...

Page 5: ...ver the secondary combustion tubes before exiting via the 4 Attach the pedestal front frame to the sides The pedestal front should go over not inside of the side panels Use three 3 self tapping screws provided in the hardware pack on each side to attach both pedestal sides to the pedestal front figure 4 5 Position ash drawer support into assembled ped estal Figure 5 and secure from rear with two 2...

Page 6: ...nal Blower Assembly note the position of the blower opening in the rear of the stove 12 Place blower gasket onto blower assembly Figure 8 so as not to obstruct the air flow from the fan 13 Mount the blower assembly to the back of the stove Figure 9 aligning the fan opening to the opening in the back of the stove Secure with four sheet metal screws 14 Route the power cord away from stove Do not all...

Page 7: ... HT US ULC S629 CDN listed manufactured chimney 5 Use round 6 152mm dia minimum 24 MSG black or 26 MSG blue steel stove pipe to connect the stove to the chimney DO NOT USE GALVANIZED DUCT PIPE AS A CONNECTOR Secure pipe sections with three 3 sheet metal screws no more than a maximum of 3 76mm apart in each stove pipe and or elbow joint to firmly hold the pipe sec tions together DO NOT CONNECT THIS...

Page 8: ...82 2010 Canadian Standard ULC S627 00 11 Always locate stove to provide a source of fresh air into the room where the unit is installed Failure to do so may result in air starvation of other fuel burning appliances and the possible develop ment of hazardous conditions 12 30 5cm 12 30 5cm CORNER CLEARANCES Fig 11 Top View Minimum Corner Clearances from Combustible Surfaces CAUTION REPLACE FIREBRICK...

Page 9: ...UTION NEVER OPERATE STOVE WITH MISSING OR CRACKED FIRE BRICKS Fig 13a Step 1 Bottom Firebrick Installation Two 2 FF Size Two 2 T Size Two 2 X Size One 1 Y Size One 1 Z Size X T F F Y T X F F Z Fig 13b Step 2 Side Firebrick Installation Four 4 A Size Two 2 M Size Fig 13c Step 3 Back Firebrick Installation Four 4 A Size A A A A X T F F Y T X F F Z M A A M A A F G F F Y T X F F Z M A A M A A A Size 9...

Page 10: ...must have at least 18 46cm of clearance be tween any horizontal piping and the ceiling 4 The pipe cannot extend into the chimney flue see figure 14 5 Secure pipe elbow sections with three sheet metal screws at each joint to make the piping rigid Screws may be no more than a maximum of 3 76mm apart 6 It is recommended that no more than two 2 90 degree bends be used in the stovepipe instal lation Th...

Page 11: ... chimney provides a natural draft which allows oxygen to be continuously introduced into the appliance so that proper combustion is possible Insufficient draft will not allow this stove operate properly NOTICE Always provide a source of fresh air into the room where the stove is located Failure to do so may result in air starvation of other fuel burn ing appliances and the possible development of ...

Page 12: ... Carefully follow the chimney manufacturer s stated requirements and clearances Use the chimney manu facturer s attic guards roof supports flashing radiation shields and fire stops when passing through a ceiling Use a listed wall pass thru when passing through a combustible wall Do not use makeshift compromises during installation See Appendix on page 24 WARNING DO NOT USE A SINGLE WALL CON NECTIO...

Page 13: ...ce company if you cannot find a qualified expert CAUTION NOT ALL FIREPLACES ARE SUIT ABLE FOR CONVERSION TO ACCOMMODATE A WOOD STOVE CHECK WITH A QUALIFIED EXPERT Many prefabricated fireplaces are of the zero clearance fireplace category These consist of multi layered metal construction They are designed with enough insulation and or air cooling on the base back and sides so they can be safely ins...

Page 14: ...24 61cm of stone 4 Install the stovepipe into the thimble as far as pos sible without extending past the flue lining see figures 14 15 on pages 10 11 5 A small airspace about 1 2 13mm should remain between the stovepipe and thimble to allow for expansion of the pipe Seal this airspace with high temperature caulking or ceramic wool 6 Secure and seal the damper in the closed posi tion using high tem...

Page 15: ... fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness D Chimney Section Pass through Solid insulated listed factory built chimney length with an inside diameter 2 51mm larger than the chimney connec tor and having 1 25 4mm or more of insulation serving as a pass through for a single wall sheet steel chimney connector of minimum 24...

Page 16: ...s of very small organic liquid droplets If these droplets condense they form a sticky tar like substance called creosote When operated properly this stove is designed to burn these droplets Burning these droplets releases heat that would otherwise be lost up the chimney as smoke Following the instructions below will help you operate your stove properly to maximize the stove s perfor mance Actual p...

Page 17: ...r with a generous amount of kin dling in a teepee fashion and a few small pieces of wood 4 Ignite the paper and leave the door open slightly DO NOT LEAVE STOVE UNATTENDED WITH DOOR OPEN Except while tending the fire operating the stove with the feed door open or ash clean out cover removed may cause over firing resulting in unsafe operating conditions 5 Add large pieces of wood as the fire progres...

Page 18: ...himney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred If creosote has accumulated 3mm or more it should be removed to reduce the risk of a chimne...

Page 19: ...ve draft an unsafe condition will arise with too much air being drawn into the stove and creating an excessively hot fire This could cause over firing which runs the risk of igniting structural elements around the stove and chimney The most common experience is that of insufficient draft Under insufficient draft conditions the fire will be starved for oxygen improper or incomplete combustion occur...

Page 20: ... for a replacement before re firing the stove 2 Do not slam the door or otherwise impact the glass When closing doors make sure that logs or other objects do not protrude to impact the glass 3 Do not build fires against or that might fall against the glass 4 Do not clean the glass with materials that may scratch or otherwise damage the glass Scratches on the glass can develop into cracks or breaks...

Page 21: ...tom of channel 4 Starting at hinge side of door work gasket into channel around door unit end butt and trim to length 5 Close door and allow three to four hours for cement to set before firing appliance BLOWER MAINTENANCE The optional blower is maintenance free other than cleaning Lightly vacuum motor and air inlet to keep free of dust and dirt SERVICE HINTS continued NOTICE ANY REPLACE MENT WIRIN...

Page 22: ... 1 2B HP Hardware Pack not shown 1 Blower Option NOT included as standard equipment F 6 Optional Blower Assembly 1 F 6G Gasket Ceramic Blower 1 F 6S Screws Blower Mounting 4 2B 01 Ceramic Fiber Pad 1 2B 02 C Cast Fiber Board 9 3 x 11 x 0 5 2 2B 03 Air Tube Middle Rear 1 2B 04 Air Tube Front 1 2B 05 Retainer Clips Air Tube 3 2B 06 Bolt Retainer Clip 3 2B 07 Nickle Trim Top Plate 1 2B 08 Handle Slid...

Page 23: ... 2B 17 Hinge Pin 2 2B 18 Door Frame 1 2B 19 Door Glass 1 2B 20 Gasket 3 8 Fiberglass Glass 1 2B 21 Retainer Glass 5 2B 22 Retainer Handle Side Glass 1 2B 23 Screws Glass Retainer 12 2B 24 Gasket Door 1 18 19 20 21 24 17 23 22 X T F F Y T X F F Z A A A A X T F F Y T X F F Z M A A M A A F G F F Y T X F F Z M A A M A A Part No Description Qty 2B 11 Fire Brick Layout 2B 11A Fire Brick A size 8 2B 11FF...

Page 24: ...protector a Use formulas in step 1 above to calculate R value of proposed material s b For multiple layers add R values of each layer to determine overall R value 3 If the overall R value of the floor protector system is equal to or greater than the floor protector specifications given the alternate is acceptable Definitions Thermal conductance C BTU W hr ft2 F m2 K Thermal conductivity k Btu inch...

Page 25: ...TR002B 20120125 0 www vogelzang com SHILOH Page 25 CHIMNEY STOVE MAINTENANCE LOG DATE OF SERVICE PERFORMED BY DESCRIPTION ...

Page 26: ...VES IN HIM SHALL NOT PERISH BUT HAVE ETERNAL LIFE JOHN 3 16 MADE IN CHINA This Vogelzang heating appliance is safe when installed properly and will provide you with years of service However always exercise good judgement when you are using this stove You are dealing with FIRE Fire is inherently dangerous and must be treated with respect Stay warm and in good health Respectfully yours Proprietor DO...