Repair
WBV.PU.002.EN VX136QD V2.0
61
9.4
How the lobe puller works
Lobe puller
We recommend using two lobe pullers so the upper and lower lobes can be pulled off as simultaneously as
possible.
VX136-70/105/140/210/280QD:
part no. PBA.B001.T1
VX136-420QD:
part no. PBA.B001.T2
Alternatively
:
Combination tool for lobe change
and
Cartridge mechanical seal change
VX136-70/105QD:
part no. PBA.B033.T1
VX136-140/210/280/420QD
part no. PBA.B033.T2
1
Hexagon head bolt
2
Puller arm
3
Pressure rod
4
Stabilisation
5
Wing nut
Fig. 25: Lobe puller components
1.
Undo the four hexagon head bolts (1) and the wing nut (5) so that the puller arms (2) can be moved.
2.
Hook the two puller arms (2) into the groove provided on the lobe
Fig.
"Hooking puller arm into
lobe".
3.
Tighten the wing nut (5) and hexagon head bolts (1) with approx. 50 Nm.
4.
Tighten the pressure rod (3) to dismount the lobe
Fig.