VODASAFE AquaEye Instruction Manual Download Page 3

a

qu

aeye® instruction manu

al

a

qu
aeye® instruction manu

al

vodasafe.ca

vodasafe.ca

5

4

Intended Use 

USES 

AquaEye® is intended for use identifying 

human bodies underwater. Using ultra-

sound and artificial intelligence technol-

ogies, AquaEye® will scan open water 

areas up to 50 meters in accordance 

with instructions contained herein and 

display visual representations of victims 

within the search area. The display allows 

emergency responders to locate and 

respond to drowning victims. AquaEye® 

is a life-saving aid for first responders and 

will not prevent drowning or injury. 
AquaEye® is intended for use in unob-

structed open bodies of water, including 

the following environments: 

• lakes and oceans, 

• retention ponds and swimming holes,

• rivers with limited underwater debris. 

USERS 

AquaEye® is intended for use by  

trained first responders, including: 

• lifeguards, 

• search and rescue, 

• police, 

• firefighters, 

• armed forces, 

• paramedics 

• first aid personnel. 

Improper use can put individuals at risk 

and result in the device being damaged. 

AquaEye® is to be operated only under 

the conditions of use described in this 

documentation. 

EXCLUDED USES 

AquaEye® is not intended for use in small, 

enclosed bodies of water, including: 

• submerged vehicles and buildings, 

• pools, wave pools and water slides,

• holding tanks and wells. 

Device Safety 

Precautions 

All operators should review these  

safety considerations before placing 

AquaEye® into service. These operating 

instructions describe the functions and 

proper operation of AquaEye®. This 

manual does not substitute for in-person 

or video training. Proper emergency 

response procedures require that oper-

ators be thoroughly familiar with proper 

device operation. 
Follow all recommended maintenance 

instructions. If a problem occurs, obtain 

service immediately. Do not use the 

device until it has been inspected by 

appropriate personnel. 
Follow recommended storage tempera-

ture instructions. Do not leave the device  

in direct sunlight for extended periods of 

time. If temperature damage is suspected, 

obtain service immediately and do not use 

the device until it has been inspected by 

appropriate personnel. 
AquaEye® is IP68 rated up to 5 meters. 

Submerging AquaEye® to depths greater 

than 5 meters may damage the device.  

If damage is suspected due to exceeding 

depth rating, obtain service immediately 

and do not use the device until it has  

been inspected by appropriate personnel. 
There are no user replaceable parts in 

AquaEye®. Do not disassemble the device. 

A shock hazard exists. Refer all problems 

to authorized service personnel. 
Subject to natural battery decline,  

AquaEye® must only be used if it  

operates in “as new” condition. 
The use of third-party accessories  

is not recommended. VodaSafe Inc. 

makes no representations or warranties 

regarding the performance or effective-

ness of its products when used with  

third-party accessories.

SAVE THIS INSTRUCTION MANUAL FOR FUTURE USE.

Operator Safety 

Precautions 

Do not use AquaEye® until entry to the 

water has been determined to be safe, 

including, without limitation, that the  

body of water be: 

• free of electrical current,

• free of hazardous substances, 

• free of unsafe currents, 

• free of hazardous waves or tsunami risk,

• free of submerged debris. 
Do not attempt to perform a water rescue 

unless you are trained to do so. 
Do not attempt to perform an ice rescue 

unless you are trained to do so.
AquaEye® floats its own weight. It is not  

a personal floatation device. Never pro-

ceed with a rescue or recovery without 

following life-saving best practices for  

the operator’s personal safety. 
AquaEye® contains a high capacity  

lithium battery and hazardous voltage  

circuitry. Do not use AquaEye® if the 

enclosure is damaged. Opening the 

device may result in a severe electric 

shock. There is also a risk of battery 

explosion if the device’s temperature 

range is exceeded.

Limited Warranty 

VodaSafe Inc. provides a non-transferable 

one (1) year limited warranty from the date 

of purchase of a new AquaEye®. This 

limited warranty covers manufacturing and 

material defects of AquaEye®. Exceptions 

are natural battery decline as well as dam-

age caused by improper use or disassem-

bly of the device by unauthorized persons. 
Please ensure your AquaEye® has been 

registered at: 

vodasafe.ca/registration 

upon purchase. 
VodaSafe Inc. offers ongoing AquaEye® 

maintenance services for an additional 

fee. Both scheduled maintenance and 

owner-requested maintenance are  

available in order to maintain detailed 

product specifications. Contact us at: 

vodasafe.ca

 for more information  

regarding maintenance plans. 

NATURAL BATTERY DECLINE 

AquaEye® devices contain lithium ion  

batteries. A lithium battery’s lifespan 

is based on its “chemical age,” which 

includes charge cycles and device usage 

patterns. VodaSafe Inc. anticipates that 

AquaEye® batteries will maintain 70%  

of their charge capacity through 100 

charge cycles. VodaSafe’s Maintenance 

Agreement excludes natural battery 

decline. Subject to availability, the  

device Owner may opt for a new  

battery for an additional cost. 

READ ALL INSTRUCTIONS BEFORE OPERATING AQUAEYE®.

Summary of Contents for AquaEye

Page 1: ...AquaEye aquaeyeTM vodasafe ca instruction manual...

Page 2: ...hile we hope that AquaEye helps saves lives there are certain things that we do not promise Other than as expressly set out in this documentation neither VodaSafe Inc nor distributors of AquaEye make...

Page 3: ...ceable parts in AquaEye Do not disassemble the device A shock hazard exists Refer all problems to authorized service personnel Subject to natural battery decline AquaEye must only be used if it operat...

Page 4: ...very high temperatures for example in a vehicle in extremely hot conditions doing so may result in permanent damage Do not attempt to open or disassemble AquaEye Doing so may result in injury or deat...

Page 5: ...to power off AquaEye C e d B a b aquaeye parts power range button a C B D E AquaEye Parts About AquaEye 2 1 1 X AquaEye 1 X Storage Case 1 X AC Adaptor 1 X AquaEye Charging Dock AquaEye is an advanced...

Page 6: ...etting up for charging The device is charged When fully charged the screen indicates battery full Remove the device and power off Place the charging dock on a counter or table The charging dock should...

Page 7: ...g scenarios will better inform you of your underwater environment and will increase success rates in finding missing persons quickly Echo Map Display will allow you to better understand your underwate...

Page 8: ...can speeds per 90 scan range short 10 m 5 sec 15 sec 30 sec medium 20 m long 50 m time 70 10m 10m 20 20 30 30 40 40 50 30 150 50 LONG Range The screen will turn on trigger use Pull the trigger to star...

Page 9: ...e f Live cursor Upon completion of a scan by releasing the trigger the cursor becomes live and acts as a compass NOTE Do not pull the trigger unless you want to begin a new scan Pulling the trigger w...

Page 10: ...When possible users should familiarize themselves with different environments to increase AquaEye knowledge Greater depth Greater depths can be scanned by tilting the wrist and pointing further down...

Page 11: ...bstacles The display can teach you about underwater obstacles which may impede AquaEye s line of sight NOTE It may be advantageous to perform scans from a particular location in your swim area based o...

Page 12: ...the sonar will not penetrate the water and echoes and objects could be missed potential causes possible solutions Cool sensor If device has been stored at high temperatures submerge device to cool se...

Page 13: ...re advance to waist deep water before scanning Dock scanning When scanning from a dock lay down on your chest and use both hands for added stability NOTE Due to the nature of the fan shaped beam the a...

Page 14: ...0 C for example in a vehicle in extremely hot conditions as AquaEye will not operate and or charge and may be permanently damaged NOTICE VodaSafe offers AquaEye training to help customers become more...

Page 15: ...ironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instruction manual may cause harmful interference to radio communica...

Page 16: ...arranties are based on final approval of normal wear and tear Please contact VodaSafe or your distributor for more information VodaSafe provides annual maintenance for more information go to vodasafe...

Reviews: